You are on page 1/ 92

Technical Service Manual

Wave-Touch™ & IQ-Touch™


Front-Load Dryer

Models
EIGD55H, EIED55H, EWED65H, EWGDS65H
EWMED65H & EWMGD65H

Publication #5995523544 Revision B August 2010


Basic Information
Safe Servicing Practices For All Appliances
Avoid personal injury and/or property damage by observing important Safe Servicing Practices.
Following are some limited examples of safe practices:
1. DO NOT attempt a product repair if you have any doubts as to your ability to complete the repair in a safe and
satisfactory manner.
2. Always use the correct Replacement Parts as indicated in the parts documentation. Substitutions may defeat
compliance with Safety Standards Set For Home Appliances. Do not exceed maximum recommended wattage
on light bulb replacements. Doing so could blow fuses and/or damage transformers.
3. Before servicing or moving an appliance:
• Remove power cord from the electrical outlet, trip circuit breaker to the OFF position, or remove fuse.
• Turn off water supply if applicable.
4. Never interfere with the proper operation of any safety device.
5. Use ONLY REPLACEMENT PARTS CATALOGED FOR THIS APPLIANCE. Substitutions may defeat
compliance with Safety Standards Set For Home Appliances.
6. GROUNDING: The standard color coding for safety ground wires is GREEN, or GREEN with YELLOW
STRIPES. Ground leads are not to be used as current carrying conductors. It is EXTREMELY important that
the service technician reestablish all safety grounds prior to completion of service. Failure to do so will create
a hazard.
7. Prior to returning the product to service, ensure that:
• All electrical connections are correct and secure.
• All electrical leads are properly dressed and secured away from sharp edges, high-temperature components,
and moving parts.
• All non-insulated electrical terminals, connectors, heaters, etc. are adequately spaced away from all metal
parts and panels.
• All safety grounds (both internal and external) are correctly and securely connected.
• All panels are properly and securely reassembled.
• Gas and water supplies are turned ON if shut off prior to service.

ATTENTION!!!
This service manual is intended for use by persons having electrical and mechanical training and a level
of knowledge of these subjects generally considered acceptable in the appliance repair trade. Electrolux
Home Products, Inc. cannot be responsible, nor assume any liability, for injury or damage of any kind
arising from the use of this manual.

© 2010 Electrolux Home Products, Inc.

1-1
Basic Information
Table of Contents Reinserting Hole Plug ................................................ 2-20
Reattaching Door Assembly ...................................... 2-20
Section 1 Basic Information .................................. 1-1 Reversing Trim Ring .................................................. 2-21
Reinstalling Trim Ring ............................................... 2-21
Safe Servicing Practices............................................ 1-1 Reinstalling Trim Plug................................................ 2-21
Table of Contents ...................................................... 1-2 Accessories ............................................................... 2-22
Important Safety Instructions ..................................... 1-4 Matching Storage Pedestal........................................ 2-22
Protect Children ......................................................... 1-4 Dryer Stacking Kit ...................................................... 2-22
Prevent Fire ............................................................... 1-4 Dryer Stacking Instructions........................................ 2-23
Product Specifications Wave-Touch™ ...................... 1-5 Kit Components ......................................................... 2-23
Product Specifications IQ-Touch™ ........................... 1-5 Preparing to Stack ..................................................... 2-23
Serial Number Breakdown......................................... 1-5 Preparing Dryer for Stacking ..................................... 2-23
Quick Reference Sheet ............................................. 1-6 Preparing Washer for Stacking .................................. 2-24
Language of Laundry................................................. 1-7 Prepare Top Surface of Washer ................................. 2-24
Stacking Dryer ........................................................... 2-24
Section 2 Installation............................................... 2-1 Removing Stacked Dryer ........................................... 2-25

Important Safety Instructions ..................................... 2-1 Section 3 Electronic Control................................... 3-1


Safety Precautions .................................................... 2-1
Tools and Materials Needed for Installation .............. 2-2 Control Panel (User Interface Layout)
Dryer Installation Dimensions .................................... 2-3 Wave-Touch™ ........................................................... 3-1
Exhaust System Requirements ................................. 2-4 Selecting the Appropriate Cycle and Settings
Install Male Fittings in Correct Direction .................... 2-5 Overview.................................................................... 3-1
Exhaust Direction ...................................................... 2-5 Demo Mode ............................................................... 3-1
Manufactured or Mobile Home Installation ................ 2-5 Wave-Touch™ Dryer Options Chart .......................... 3-2
Clearance Requirements ........................................... 2-6 Wave-Touch™ Dryer Options Chart (Steam Model). 3-3
Installation in a Recess or Closet .............................. 2-6 Control Panel (User Interface Layout) IQ-Touch™ .... 3-4
Electrical System Requirements................................ 2-7 Selecting the Appropriate Cycle and Settings
3-Wire Power Supply Cord Kit ................................... 2-7 Overview.................................................................... 3-4
4-Wire Power Supply Cord Kit ................................... 2-7 Demo Mode ............................................................... 3-4
Outlet Receptacle ...................................................... 2-7 IQ-Touch™ Dryer Options Chart ............................... 3-5
Electrical Requirements for Gas Dryer ...................... 2-7 Cycle Selection .......................................................... 3-6
Electrical Installation .................................................. 2-8 Auto Dry Cycles ......................................................... 3-6
For a Grounded, Cord-connected Dryer: Normal ....................................................................... 3-6
(U.S.A. Electric Dryer) ............................................... 2-8 Towels ........................................................................ 3-6
For a Grounded, Cord-connected Dryer: Mixed Load ................................................................ 3-7
(Canada Electric Dryer) ............................................. 2-8 Heavy Duty ................................................................ 3-7
Gas Dryer .................................................................. 2-8 Bulky/ Bedding........................................................... 3-7
Electrical Connection (non-Canada) 3 Wire Cord ..... 2-9 Casual ....................................................................... 3-7
Electrical Connection (non-Canada) 4 Wire Cord ..... 2-10 Active Wear ............................................................... 3-7
Gas Supply Requirements......................................... 2-11 Delicate...................................................................... 3-7
Gas Connection ......................................................... 2-11 Time Dry Cycles ........................................................ 3-7
Water Connection (Steam Model Only) ..................... 2-12 Time Dry .................................................................... 3-7
General Installation.................................................... 2-13 Fast Dry ..................................................................... 3-7
Wave-Touch™ Installation Cycle .............................. 2-14 Touch Up (non-steam models only) ........................... 3-7
IQ -Touch™ Installation Cycle ................................... 2-14 Perfect Steam (steam models only) ........................... 3-7
Reversing Door.......................................................... 2-15 My Favorites (Wave-Touch™).................................... 3-8
Preparing to Reverse Door Swing ............................. 2-15 Drying Temperature .................................................. 3-9
Removing Trim Ring .................................................. 2-15 Auto Dry.................................................................... 3-9
Removing Door from Hinge ....................................... 2-15 Maximum Temp ........................................................ 3-9
Removing Hinge from Front Panel ........................... 2-16 High Temp................................................................. 3-9
Removing Door Lock from Front Panel ..................... 2-16 Med High Temp......................................................... 3-9
Reattaching Door Lock to Font Panel........................ 2-17 Medium Temp ........................................................... 3-9
Reattaching Hinge to Front Panel .............................. 2-17 Med Low Temp ......................................................... 3-9
Removing Striker Plate .............................................. 2-18 Low Temp ................................................................. 3-9
Removing Latch Indicator .......................................... 2-18 Air Fluff Temp............................................................ 3-9
Removing Hole Plug .................................................. 2-19 Time Dry ................................................................... 3-9
Reinserting Latch Indicator ........................................ 2-19
Reattaching Striker Plate ........................................... 2-20

1-2
Basic Information
Options ..................................................................... 3-10 Latch Indicator ........................................................... 4-4
Add Steam (steam models only) .............................. 3-10 Door Strike................................................................. 4-4
Extended Tumble ...................................................... 3-10 Outer Door Glass....................................................... 4-4
Wrinkle Release (IQ-Touch™) .................................. 3-10 Door Hinge ................................................................ 4-5
Wrinkle Release (Wave-Touch™ ) ............................ 3-10 Lint Trap ..................................................................... 4-5
Gentle Tumble........................................................... 3-11 Air Duct Cover ........................................................... 4-5
Delicate Heat ............................................................ 3-11 Top Panel ................................................................... 4-6
Sanitize ..................................................................... 3-11 Console and User Interface ....................................... 4-6
Chime ....................................................................... 3-11 Front Panel ................................................................ 4-7
Delicate Heat ............................................................ 3-11 Door Switch ............................................................... 4-7
Damp Alert ............................................................... 3-11 Control Assembly ...................................................... 4-8
Shrink Guard ............................................................ 3-11 Control Box Bracket ................................................... 4-8
User Interface Features ............................................ 3-12 Interior Light .............................................................. 4-9
Save as Favorite ....................................................... 3-12 Top Rear Brace.......................................................... 4-9
Set Prefs ................................................................... 3-12 Rear Panel ................................................................. 4-9
User Guides.............................................................. 3-12 Inlet Thermistor.......................................................... 4-10
Stain Guides ............................................................. 3-12 Moisture Sensing Bar ................................................ 4-10
Control Lock (Wave-Touch™) ................................... 3-12 Belt Removal (Wave Touch™) ................................... 4-11
Control Lock (IQ-Touch™) ........................................ 3-12 Belt Removal (IQ Touch™) ........................................ 4-11
My Favorites (Wave-Touch™)................................... 3-12 Front Inner Panel and Drum ...................................... 4-11
Save as Favorite ....................................................... 3-13 Roller Assembly......................................................... 4-12
Setting Preferences .................................................. 3-14 Front Air Duct............................................................. 4-12
Custom Mode ........................................................... 3-14 Exhaust Thermal Limiter ............................................ 4-13
Install Cycle (Wave-Touch™).................................... 3-15 Exhaust Tube ............................................................. 4-13
Install Cycle (IQ -Touch™)........................................ 3-15 Outlet (Exhaust) Thermistor ...................................... 4-13
Reset (Wave-Touch™) ............................................. 3-16 Belt Tensioner (Wave Touch™) .................................. 4-14
Reset (IQ-Touch™)................................................... 3-16 Belt Tensioner (IQ Touch™) ....................................... 4-14
Contrast .................................................................... 3-16 Motor and Blower Assembly ...................................... 4-15
Brightness ................................................................ 3-17 Motor and Blower Assembly Separation.................... 4-16
Volume...................................................................... 3-17 Drum Vane ................................................................. 4-17
Language.................................................................. 3-17 Rear Heat Duct .......................................................... 4-17
Cycle Description...................................................... 3-17 Heat Shield ................................................................ 4-17
Status Display ........................................................... 3-17 Electric Heater Function ............................................ 4-18
Drum Light ................................................................ 3-17 Heater Assembly ....................................................... 4-18
Diagnostics and Error Codes.................................... 3-18 Thermal Limiter and Safety Thermostat .................... 4-18
Reading Error Codes ................................................ 3-18 Gas Heater Assembly Breakdown ............................. 4-19
To Clear Latest Stored Error Code ........................... 3-18 Thermal Limiters ........................................................ 4-19
Exiting Diagnostic Mode ........................................... 3-18 Gas Valve Wire Harness Connections ....................... 4-19
Diagnostic Mode ....................................................... 3-19 Gas Valve Coil ........................................................... 4-19
To Start the Diagnostic Mode ................................... 3-19 Manifold and Burner Assembly Breakdown ............... 4-20
Error Code Chart ..................................................... 3-20 Combustion Tube ....................................................... 4-21
IQ-Touch™ Available Cycle Settings, Pre-Sets
and Options Chart .................................................... 3-22
Wave-Touch™ Available Cycle Settings, Section 5- Troubleshooting ..................................... 5-1
Pre-Sets and Options Chart ..................................... 3-23
Wave-Touch™ with Steam, Available Cycle Troubleshooting Chart ............................................... 5-1
Settings, Pre-Sets and Options Chart ...................... 3-24 Electrical Tests For Gas And Electric Dryers ............. 5-3
Electrical Tests For Electric Dryers ............................ 5-4
Section 4- Component Teardown .......................... 4-1 Electrical Tests For Gas Dryers ................................. 5-5

Warnings and Cautions ............................................. 4-1 Section 6- Wiring Diagrams .................................... 6-1
Door Components ..................................................... 4-2
Door Trim Ring ........................................................... 4-2 Wiring Diagram Model EIED55H ............................... 6-1
Door Assembly .......................................................... 4-2 Wiring Diagram Model EIGD55H............................... 6-2
Latch Plate and Door Latch ....................................... 4-3 Wiring Diagram Model EWED65H............................. 6-3
Inner Door Glass ....................................................... 4-3 Wiring Diagram Model EWGD65H ............................ 6-4
Door Latch Assembly ................................................ 4-3 Wiring Diagram Model EWMED65 ............................ 6-5
Wiring Diagram Model EWMGD65 ............................ 6-6

1-3
Basic Information

Important Safety Instructions Before the dryer is removed from service or discarded,
remove the dryer door to prevent accidental
Safety Precautions entrapment.
Failure to comply with these warnings could result in
Do not attempt to install, operate or service the unit until serious personal injuries.
you have read the safety precautions in this manual.
Safety items throughout this manual are labeled with a Prevent Fire
Danger, Warning, or Caution based on the risk type.
Do not dry items that have been previously cleaned in,
Definitions soaked in, or spotted with gasoline, cleaning solvents,
kerosene, waxes, etc. Do not store these items on or near
This is the safety alert symbol. It is used to alert the dryer. These substances give off vapors that could
you to potential personal injury hazards. Obey all ignite or explode.
safety messages that follow this symbol to avoid possible
Do not place items exposed to cooking oils in your dryer.
injury or death.
Items contaminated with cooking oils may contribute to a
chemical reaction that could cause a load to catch fire.
DANGER indicates an imminently hazardous To prevent fire, do not use heat to dry items containing
situation which, if not avoided, will result in death plastic, foam rubber or similarly textured rubberlike
or serious injury. materials, or items containing feathers or down. Use Air
Fluff (No Heat) only.
Clean the lint screen before or after each load. The
interior of the dryer, lint screen housing and exhaust
WARNING indicates a potentially hazardous duct should be cleaned approximately every 18 months
situation which, if not avoided, could result in by qualified service personnel. An excessive amount of
death or serious injury. lint buildup in these areas could result in inefficient drying
and possible fire.
Do not operate the dryer if the lint screen is blocked,
damaged or missing. Fire hazard, overheating and
CAUTION indicates a potentially hazardous damage to fabrics can occur. If your dryer has a drying
situation which, if not avoided, may result in minor rack, always replace the lint screen when finished using
or moderate injury. the drying rack.
Keep area around exhaust opening and surrounding
areas free from the accumulation of lint, dust and dirt.
Do not obstruct the flow of ventilating air. Do not stack or
Indicates installation, operation, or maintenance place laundry or throw rugs against the front or back of
information which is important but not hazard the dryer.
related.
Do not spray any type of aerosol into, on or near dryer at
any time.
Child Safety Do not use fabric softeners or products to eliminate static
Do not allow children to play on or in the dryer.Close unless recommended by the manufacturer of the fabric
supervision of children is necessary when the dryer softener or product.
is used near children. As children grow, teach them the Failure to comply with these warnings could result in fire,
proper, safe use of all appliances. explosion, serious bodily injury and/or damage
Destroy the carton, plastic bag and other packing to the rubber or plastic parts of the dryer.
materials after the dryer is unpacked.
Children might use them for play. Cartons covered with
rugs, bedspreads or plastic sheets can become
airtight chambers.
Keep laundry products out of children’s reach. To prevent
personal injury, observe all warnings on product
labels.

1-4
Basic Information
Product Specifications Wave Product Specifications IQ
Touch™ Dryer Touch™ Dryer
2 Premium Colors White and 1 Premium Color
Enhanced LCD Controls (with larger trilingual display) Superior drying – Even & Gentle
Reversing Drum Reversible Door
Quiet (56 dBA maximum) Push2Open: Door & Pedestal
11 Standard and 3 Favorite Cycles with custom Large Capacity (8 cu. ft.)
settings to reach 42 Total Cycles Intelligent and Adaptive LCD Controls
Multiple User Mode – 3 User Modes with Favorite Electrolux Blue LEDs
and Custom Cycles Custom Cycles Including My Favorite
8 Timed Dry Options Quiet (59 dBA maximum)
Shrink Guard Top CU Rating
Drum Light with manual switch 11 Cycles with 4 Dryness levels and 5
2 Temperature Selections (7 total) Temperature Selections
Steam NSF Rated Sanitary Cycle
Fastest Cycle Time Fastest Cycle Time
Cycles Cycles
NSF Certified NSF Certified
Heavy Duty Heavy Duty
Bulky/Bedding Bulky/Bedding
Mixed Load Mixed Load
Towels Towels
Normal Normal
Active Wear – Use for sports/workout gear Quick Dry – The fastest cycle in the industry
Quick Dry – The fastest cycle in the industry Casual – Use for Permanent Press items
Casual – Use for Permanent Press items Delicate – Gentler than any cycle available
Delicate – Gentler than any cycle available Touch Up
Touch Up Time Dry – Up to 90 minutes
Time Dry – Up to 90 minutes My Favorite – Programmable by consumer
My Favorite – Programmable by consumer
Additional Options
Additional Options
Damp Alert – For items that will be ironed.
Damp Alert – For items that will be ironed.
Control Lock – to prevent accidental operation by
Control Lock – to prevent accidental operation by
children
children
5 Temperature Selections
7 Temperature Selections
Wrinkle Rid – Extends tumble time so wrinkles do
Wrinkle Rid – Extends tumble time so wrinkles do
not set.
not set.
Soft Heat – Reduces the temperature as the cycle
Soft Heat – Reduces the temperature as the cycle
progresses to prevent damage.
progresses to prevent damage.

Model Number Breakdown Serial Number Breakdown


Each model follows the following nomenclature:
E ..................for Electrolux 4 D 8 2 8 1 2 3 4 5
I ..................for IQ Touch
W ..................for Wave Touch Incremented unit number
FLW ..............for Front Load Washer Production Week
Last Digit of Production Year
ED ................for Electric Dryer
Product Identification
GD ................for Gas Dryer
Manufacturing Facility
MED/MGD ....Steam Electric/Steam Gas Dryer
P ....................for Pedestal

1-5
Basic Information
QUICK REFERENCE SHEET
SPECIFICATION ELECTRIC MODELS GAS MODELS

Electrical
Volts 120/208 or 120/240 120/208 or 120/240 120
Amps (circuit) 30 15
Motor wattage 200-290 Watts 200-290 Watts
Heat input (Watts @ 240 VAC) 4300/5500 ---
Heat input (BTU/Hr.) --- 22,000
Auto. Elec. Ignition --- Yes

Drum
Size (Cu. Ft.) 8.0 8.0
Finish Powder Paint Epoxy Powder Paint Epoxy
R.P.M. 48 - 54 48 - 54

Airflow CFM 200 200

DRUM TEMPERATURES
(Max. opening on 3rd cycle)
Maximum 120° - 160° 120° - 180°
Medium 110° - 140° 105° - 145°
Low 95° - 130° 95° - 130°

Dimension (Inches)
Height 38” 38”
Width 27” 27”
Depth 31.5” 31.5”

Vent Capability 4-Way 4-Way

Top Finish Powder Paint Enamel Powder Paint Enamel

Port Opening (Sq. In.) 235 235

Component Resistances* Electric Models Gas Models

Drive motor (120 volt, 60 Hz, 1/4 h.p. 1725 rpm)


Motor Start Winding 4.5 Ohms 4.5 Ohms
Motor Run Winding 3.8 Ohms 3.8 Ohms

Heating Element 26.4 Ohms

Control Thermistor 50K Ohms 50K Ohms


+/- 5% @ 77° F +/- 5% @ 77° F
Burner Assembly
Ignitor --- 50 - 400 Ohms
Secondary Coil --- 1200 Ohms
Booster Coil --- 1320 Ohms

* +/- 10% @ 77° F

1-6
Basic Information
The Language of Laundry

Machine Wash Special Bleaching Dryer Ironing Dry


Instructions Care Instructions Instructions Instructions Cleaning

Normal Hand Bleach Normal DO NOT Low Heat Dry Clean


Wash Wash as Needed Dry Machine Dry

Med. Heat Dry Clean


Permanent DO NOT Non-chlorine Permanent Line Dry w/ Any
Press Wring Bleach as Needed Press Solvent

High Heat
Drip Dry
Dry Clean
Gentle DO NOT Gentle w/Petroleum
Cycle Bleach Setting Solvent
DO NOT
Dry Flat Steam

DO NOT DO NOT Dry Clean


Machine Wash Tumble Dry w/Solvents
Other Than
Dry in DO NOT Trichloroethylene
Shade Iron

No Heat
Cold
(<85ºF) DO NOT
Dry Clean

Low Heat
Warm
(<105ºF)

Normal/
Med. Heat
Hot
(<120ºF)

High
Heat
Hot
(<140ºF)

1-7
Basic Information

Notes

1-8
Installation Information
Recognize safety symbols, words and labels:
Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described
below:
This symbol alerts you to situations that may cause serious body harm, death or
property damage.

This symbol alerts you to situations that may cause bodily injury or property damage.

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY WHEN USING A WAVE-TOUCH™ OR
IQ-TOUCH™ DRYER, FOLLOW BASIC SAFETY PRECAUTIONS INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE OPERATING THE DRYER.
BEFORE PERFORMING ANY TYPE OF SERVICE OR INSTALLATION, MAKE SURE THAT ELECTRIC
POWER TO THE DRYER IS DISCONNECTED.
TO AVOID THE POSSIBILITY OF EXPLOSION OR FIRE, DO NOT STORE OR USE COMBUSTIBLE,
FLAMMABLE, OR EXPLOSIVE LIQUIDS OR VAPORS (SUCH AS GASOLINE) INSIDE OR IN THE VICINITY
OF THIS OR ANY OTHER APPLIANCE.
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG GROUNDING PLUG FOR PROTECTION AGAINST
POSSIBLE ELECTRIC SHOCK HAZARDS. PLUG IT ONLY INTO A DEDICATED, GROUNDED ELECTRICAL
OUTLET. WHEN ONLY A STANDARD TWO-PRONG ELECTRICAL OUTLET IS AVAILABLE, THE CUSTOMER
MUST HAVE IT REPLACED WITH A DEDICATED, PROPERLY GROUNDED THREE-PRONG ELECTRICAL
OUTLET BEFORE USING THIS APPLIANCE. DO NOT UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER PLUG. DO NOT
USE AN EXTENSION CORD. DO NOT USE A POWER CORD THAT IS FRAYED OR DAMAGED.
THE USE OF A GROUND FAULT INTERRUPTER (GFI) IS NOT RECOMMENDED.
DO NOT INSTALL OR USE A DAMAGED APPLIANCE. IF YOU RECEIVE A DAMAGED APPLIANCE,
IMMEDIATELY CONTACT YOUR DEALER OR BUILDER.
DO NOT USE THE DRYER UNTIL IT HAS BEEN PROPERLY INSTALLED BY A QUALIFIED INSTALLER
ACCORDING TO THESE INSTALLATION INSTRUCTIONS. THE INSTALLER MUST SHOW THE CUSTOMER
THE LOCATION OF THE POWER PLUG SO THAT THEY KNOW WHERE AND HOW TO DISCONNECT
POWER TO THE DRYER.
DO NOT INSTALL, REPAIR, OR REPLACE ANY PART OF THE DRYER UNLESS SPECIFICALLY
RECOMMENDED IN THE LITERATURE ACCOMPANYING IT. A QUALIFIED SERVICE TECHNICIAN SHOULD
PERFORM ALL OTHER SERVICE.

Electrolux Home Products Inc. cannot be held responsible for damage to property or injury to persons
caused by failure to comply with the installation, maintenance and safety instructions contained in this
Service Manual.

2-1
Installation Information

DESTROY CARTON, PLASTIC BAGS, AND ANY EXTERIOR WRAPPING MATERIAL IMMEDIATELY
AFTER THE DRYER IS UNPACKED. CHILDREN SHOULD NEVER USE THESE ITEMS FOR PLAY.
CARTONS COVERED WITH RUGS, BEDSPREADS, PLASTIC SHEETS OR STRETCH WRAP MAY
BECOME AIR TIGHT CHAMBERS AND CAN QUICKLY CAUSE SUFFOCATION.

KEEP LAUNDRY PRODUCTS OUT OF CHILDREN’S REACH. TO PREVENT PERSONAL INJURY,


OBSERVE ALL WARNINGS ON PRODUCT LABELS.

CUT HAZARD. TO PREVENT SERIOUS INJURY FROM SHARP EDGES, WEAR WORK GLOVES
WHEN HANDLING, UNPACKING OR DISASSEMBLING UNIT.

EXCESSIVE WEIGHT HAZARD


To avoid back or other injury, have more than one person move or lift the dryer.

The electrical service to the dryer must conform with local codes and ordinances and the latest
edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code
C22.1 part 1.

What To Do If You Smell Gas:


• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.

Pre-installation Requirements
Tools and materials needed for installation:

or
or

Adjustable Phillips, straight, & Adjustable Pipe wrench LP-resistant Carpenter’s level External
pliers square bit screwdrivers wrench for gas thread tape vent hood
supply (for natural gas
or LP supply)
½” NPT union flare
3-wire or 4-wire 4 in. gas line adapters (x2) and
4 inch, rigid metal or 240 volt cord kit (10.2 cm) shutoff valve flexible gas supply line Metal foil tape
semi-rigid metal exhaust duct work (electric dr yer) clamp (gas dr yer) (gas dr yer) (not duct tape)

2-2
Installation Information
Dryer Installation Dimensions
50.6” (128.5cm)*
To clear open door 27.00”
31.50” (80cm)* (68.5cm)
To front of closed door

38.00”
(96.5cm)

Electrical
supply on
53.00” rear of unit
(134.5cm)

Centerline
Freestand dryer height for
on floor Gas supply rear vent
pipe on rear
of gas unit 3.40”
(8.5cm)
Floor line
1.4”
(3.5cm)

Dryer mounted on
optional pedestal 16.25” 18.25”
(41.5cm) (46.5cm)

Floor line

* To obtain these minimal depth dimensions, dryer must either be vented straight back 3.75”
or with a quick-turn90° elbow. Connection of water inlet hose on Steam Models (9.5cm) 13.50”
adds 3/4 in. (2 cm) to installation depth. (34.5cm)
To center ofrear vent

50.6” (128.5cm)*
To clear open door 27.00”
31.50” (80cm)* (68.5cm)
To front of closed door

75.75”
(192.5cm) Electrical
supply on
rear of unit

Centerline
height for
Gas supply rear vent
pipe on rear
of gas unit

41.00”
(104cm)

39.00”
(99cm)

* To obtain these minimal depth dimensions, dryer must either be vented straight back or with a quick-turn 90° elbow.
Connection of water inlet hose on Steam Models adds 3/4 in. (2 cm) to installation depth.

Figure 2-1.

2-3
Installation Information
Exhaust System Requirements
Use only 4 inch (10.2 cm) diameter (minimum) rigid
or flexible metal duct and approved vent hood which has
a swing-out damper(s) that open when the dryer is in
operation. When the dryer stops, the dampers automati-
cally close to prevent drafts and the entrance of insects
and rodents. To avoid restricting the outlet, maintain a
minimum of 12 inches (30.5 cm) clearance between the
vent hood and the ground or any other obstruction.
If the present system is made up of plastic duct or metal
foil duct, replace it with a rigid or semi-rigid metal duct.
In Canada and the United States if metal (foil type) duct
is installed, it must be of a specific type identified by the
appliance manufacturer as suitable for use with clothes
dryers and in the United States must also comply with
the Outline for Clothes Dryer Transition Duct, UL
standard 2158A. Also, ensure the present duct is free of
any lint prior to installing dryer duct.
The dryer must be connected to an exhaust outdoors.
Figure 2-2.
Regularly inspect the outdoor exhaust opening and
remove any accumulation of lint around the outdoor MAXIMUM LENGTH
exhaust opening and in the surrounding area. (See of 4” (10.2cm) Rigid Metal Duct
Number of 90° turns

Figure 2-2 & 2-3) VENT HOOD TYPE


(Preferred)

DO NOT ALLOW COMBUSTIBLE MATERIALS


(FOR EXAMPLE: CLOTHING, DRAPERIES AND
4” 2.5”
CURTAINS, PAPER) TO COME IN CONTACT WITH (10.2cm) louvered (6.35cm)
EXHAUST SYSTEM. THE DRYER MUST NOT BE
0 125 ft. (38.10m) 110 ft. (33.53m)
EXHAUSTED INTO A CHIMNEY, WALL, CEILING,
OR ANY CONCEALED SPACE OF A BUILDING 1 115 ft. (35.05m) 100 ft. (30.48m)
WHICH CAN ACCUMULATE LINT, RESULTING IN A 2 105 ft. (32.00m) 90 ft. (27.43m)
FIRE HAZARD. 3 95 ft. (28.96m) 80 ft. (24.38m)
DO NOT SCREEN THE EXHAUST ENDS OF THE 4 85 ft. (25.91m) 70 ft. (21.34m)
VENT SYSTEM, OR USE ANY SCREWS, RIVETS
OR OTHER FASTENERS THAT EXTEND INTO THE MAXIMUM LENGTH
of 4” (10.2cm) Semi-Rigid Metal Duct
DUCT TO ASSEMBLE THE EXHAUST
Number of 90° turns

SYSTEM. LINT CAN BECOME CAUGHT IN THE VENT HOOD TYPE


SCREEN, ON THE SCREWS OR RIVETS, (Preferred)
CLOGGING THE DUCT WORK AND CREATING
A FIRE HAZARD AS WELL AS INCREASING
DRYING TIMES. USE AN APPROVED VENT HOOD
TO TERMINATE THE DUCT OUTDOORS, AND
SEAL ALL JOINTS WITH DUCT TAPE. ALL MALE 4” 2.5”
(10.2cm) louvered (6.35cm)
DUCT PIPE FITTINGS MUST BE INSTALLED
DOWNSTREAM WITH THE FLOW OF AIR. 0 60 ft. (18.29m) 45 ft. (13.72m)
1 50 ft. (15.24m) 35 ft. (10.67m)
2 40 ft. (12.19m) 25 ft. (7.62m)
3 NOT RECOMMENDED

Figure 2-3.

2-4
Installation Information
Install Male Fittings in Correct Direction: Exhaust Direction

In installations where the exhaust system is not Directional exhausting can be accomplished by
described in the charts, the following method must be installing a quick-turn 90° dryer vent elbow directly
used to determine if the exhaust system is acceptable: to exhaust outlet of dryer. Dryer vent elbows are
(See Figure 2-4) available through your local parts distributor or
hardware store. (See Figure 2-5)

Figure 2-4.

Exhaust System Requirements

1. Connect an inclined or digital manometer between


the dryer and the point the exhaust connects to the Figure 2-5.
dryer.
2. Set the dryer timer and temperature to air fluff
]

(cool down) and start the dryer. Manufactured or Mobile Home Installation
3. Read the measurement on the manometer. 1. Installation MUST conform to current Manufactured
4. The system back pressure MUST NOT be higher Home Construction & Safety Standard, Title 24 CFR,
than 1.0 inch of water column. If the system back Part 32-80 (formerly the Federal Standard for Mobile
pressure is less than 1.0 inch of water column, the Home Construction and Safety, Title 24, HUD Part
system is acceptable. If the manometer reading is 280) or Standard CAN/CSAZ240 MH.
higher than 1.0 inch of water column, the system is 2. Dryer MUST be exhausted outside (outdoors, not
too restrictive and the installation is unacceptable. beneath the mobile home) using metal ducting that
Although vertical orientation of the exhaust system will not support combustion. Metal ducting must be
is acceptable, certain extenuating circumstances 4 inches (10.16 cm) in diameter with no obstructions.
could affect the performance of the dryer: Rigid metal duct is preferred.
1. Only the rigid metal duct work should be used. 3. If dryer is exhausted through the floor and area
2. Venting vertically through a roof may expose the beneath the mobile home is enclosed, the exhaust
exhaust system to down drafts causing an increase system MUST terminate outside the enclosure with
in vent restriction. the termination securely fastened to the mobile home
structure.
3. Running the exhaust system through an uninsulated
area may cause condensation and faster 4. Refer to previous sections in this guide for other
accumulation of lint. important exhaust venting system requirements.
4. Compression or crimping of the exhaust system will 5. When installing a gas dryer into a mobile home, a
cause an increase in vent restriction. provision must be made for outside make up air.
This provision is to be not less than twice the area of
5. The exhaust system should be inspected and
the dryer exhaust outlet.
cleaned a minimum of every 18 months with normal
usage. The more the dryer is used, the more often 6. Installer MUST anchor this (1) dryer or (2) dryer
you should check the exhaust system and vent hood mounted on pedestal to the floor with approved
for proper operation. Mobile Home Installation Kit.

2-5
Installation Information
Clearance Requirements
Installation in a Recess or Closet

DO NOT INSTALL THE DRYER:


1. In an area exposed to dripping water or out
side weather conditions.
2. In an area where it will come in contact with
curtains, drapes, or anything that will obstruct
the flow of combustion and ventilation air.
3. On carpet. Floor MUST be solid with a
maximum slope of 1 inch (2.54 cm).

1. A dryer installed in a bedroom, bathroom, recess or


closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in
the same closet as the gas dryer.
3. The dryer needs the space around it for proper
ventilation. DO NOT install dryer in a closet with a
solid door.
4. Closet door ventilation required: A minimum of
120 square inches (774.2 cm²) of opening, equally
divided at the top and bottom of door, is required.
Openings should be located 3 inches (7.6 cm) from
bottom and top of door. Openings are required to be
unobstructed when a door is installed. A louvered
door with equivalent air openings for the full length of
door is acceptable. (See Figure 2-6 & 2-7)

Figure 2-7.

To achieve an installation with 0” (0cm) clearance


for the back of the dryer (for other than straight
back venting), a quick-turn 90° dryer vent elbow
must be installed as described previously in this
manual.

Figure 2-6.

2-6
Installation Information
Electrical System Requirements
Circuit - Individual 30 amp. branch circuit fused with 30
This dryer is internally grounded to neutral
amp. time delay fuses or circuit breakers. Use separately
unless it was manufactured for sale in Canada.
fused circuits for washer and dryer. DO NOT operate a
Grounding through the neutral link is prohib-
washer and a dryer on the same circuit.
ited for: (1) new branch circuit installations, (2)
Power Supply - 3-wire or 4-wire, 240 volt, single phase, mobile homes, (3) recreational vehicles, and (4)
60 Hz, Alternating Current. areas where local codes do not permit grounding
through the neutral.

Because of potentially inconsistent voltage capa-


bilities, the use of this dryer with power created
by gas powered generators, solar powered gen- Dryers manufactured for sale in Canada have
erators, wind powered generators or any other factory-installed, 4-wire power supply cord
generator other than the local utility company is (NEMA 14-30R).
not recommended.
GFI (Ground Fault Interrupter) receptacle is not Outlet Receptacle
required. NEMA 10-30R or NEMA 14-30R receptacle to be located
so the power supply cord is accessible when the dryer is
3-Wire Power Supply Cord Kit (not supplied) in the installed position.
The dryer MUST employ a 3-conductor power supply
cord NEMA 10-30 type SRDT rated at 240 volt AC
Electrical Requirements for Gas Dryer:
minimum, 30 amp, with 3 open end spade lug connec-
tors with upturned ends or closed loop connectors and Circuit - Individual, properly polarized and grounded 15
marked for use with clothes dryers. For 3-wire cord amp. branch circuit fused with 15 amp. time delay fuse
connection instructions see Electrical Connections or circuit breaker.
For A 3-Wire System. Power Supply - 2-wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
4-Wire Power Supply Cord Kit (not supplied)
Power Supply Cord - The dryer is equipped with a 120
The dryer MUST employ a 4-conductor power supply volt 3-wire power cord.
cord NEMA 14-30 type SRDT or ST (as required) rated Grounding Connection - See “Grounding Requirements”
at 240 volt AC minimum, 30 amp, with 4 open end spade in Electrical Installation section.
lug connectors with upturned ends or closed loop con-
nectors and marked for use with clothes dryers. For
4-wire cord connection instructions see Electrical
Connections For A 4-Wire System.

2-7
Installation Information
Electrical Installation

DO NOT USE AN EXTENSION CORD WITH THIS DRYER. SOME EXTENSION CORDS ARE NOT
DESIGNED TO WITHSTAND THE AMOUNTS OF ELECTRICAL CURRENT THIS DRYER UTILIZES AND
CAN MELT, CREATING ELECTRICAL SHOCK AND/OR FIRE HAZARD. LOCATE THE DRYER WITHIN
REACH OF THE RECEPTACLE FOR THE LENGTH POWER CORD TO BE PURCHASED, ALLOWING SOME
SLACK IN THE CORD.

A U.L.-APPROVED STRAIN RELIEF MUST BE INSTALLED ONTO POWER CORD. IF THE STRAIN RELIEF
IS NOT ATTACHED, THE CORD CAN BE PULLED OUT OF THE DRYER AND CAN BE CUT BY ANY
MOVEMENT OF THE CORD, RESULTING IN ELECTRICAL SHOCK.

DO NOT USE AN ALUMINUM WIRED RECEPTACLE WITH A COPPER WIRED POWER CORD AND PLUG
(OR VICE VERSA). A CHEMICAL REACTION OCCURS BETWEEN COPPER AND ALUMINUM AND CAN
CAUSE ELECTRICAL SHORTS. THE PROPER WIRING AND RECEPTACLE IS A COPPER WIRED POWER
CORD WITH A COPPER WIRED RECEPTACLE.

For a Grounded, Cord-connected Dryer: For a Grounded, Cord-connected Dryer:


(U.S.A. Electric Dryer) (Canada Electric Dryer)
1. The dryer MUST be grounded. In the event of a 1. The dryer MUST be grounded. In the event of a
malfunction or breakdown, grounding will reduce the malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance risk of electrical shock by a path of least resistance
for electrical current. for electrical current.
2. After you purchase and install a 3 wire or 4 Wire 2. Since your dryer is equipped with a power supply
power supply cord having an equipment grounding cord having an equipment-grounding conductor and
conductor and a grounding plug that matches your a grounding plug, the plug must be plugged into
wiring system, the plug MUST be plugged into an an appropriate outlet that is properly installed and
appropriate, copper wired receptacle that is properly grounded in accordance with all local codes and
installed and grounded in accordance with all local ordinances. If in doubt, call a licensed electrician.
codes and ordinances. If in doubt, call a licensed DO NOT modify the plug provided with the appliance.
electrician.
DO NOT modify the plug you’ve installed on this Gas Dryer
appliance. 1. The dryer is equipped with a three-prong (grounding)
For a permanently connected dryer: plug for your protection against shock hazard and
should be plugged directly into a properly grounded
1. The dryer MUST be connected to a grounded
three-prong receptacle.
metal, permanent wiring system; or an equipment
grounding conductor must be run with the circuit DO NOT cut or remove ground prong from the plug.
conductors and connected to the equipment-
grounding terminal or lead on the appliance.

2-8
Installation Information
Electrical Connection
(non-Canada) - 3 Wire Cord

ELECTRICAL SHOCK HAZARD


FAILURE TO DISCONNECT POWER SOURCE
BEFORE SERVICING COULD RESULT IN
PERSONAL INJURY OR EVEN DEATH.

1. Turn off power supply to outlet.


2. Remove the screw securing the terminal block
access cover in the lower corner on the back of the
dryer.
3. Install a UL-approved strain relief according to the
power cord/strain relief manufacturer’s instructions in
the power cord entry hole below the access panel.
At this time, the strain relief should be loosely in
place.
4. Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 10-30 type SRDT,
through the strain relief.
5. Attach the power cord neutral (center wire)
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely. (See Figure 2-8 & 2-9) Figure 2-8.
6. Attach the remaining two power cord outer
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
If a terminal screw falls during cord installation,
screws securely.
it can be retrieved in the terminal screw recovery
7. Follow manufacturer’s guidelines for firmly slot below the access panel.
securing the strain relief and power cord.

ELECTRICAL SHOCK HAZARD


DO NOT MAKE A SHARP BEND OR CRIMP
WIRING/ CONDUCTOR AT CONNECTIONS.

8. Reinstall the terminal block cover.

If moving dryer from a 4-wire system and install-


ing it in a 3-wire system, move the internal ground
from the center terminal back to the GREEN
screw next to the terminal block.

Figure 2-9.

2-9
Installation Information
Electrical Connection
(non-Canada) - 4 Wire Cord
Neutral
30 Amp Ground White wire
NEMA 14-30 Green
wire
ELECTRICAL SHOCK HAZARD
FAILURE TO DISCONNECT POWER SOURCE
BEFORE SERVICING COULD RESULT IN
PERSONAL INJURY OR EVEN DEATH.
Access Cover
Screw
1. Turn off power supply to outlet. Terminal
2. Remove the screw securing the terminal block Block
access cover in the lower corner on the back of the
Line 2
dryer. Brass Terminal
3. Install a UL-approved strain relief according to the Neutral
power cord/strain relief manufacturer’s instructions in Silver Terminal
the power cord entry hole below the access panel. At
Line 1
this time, the strain relief should be loosely in place. Brass Terminal
4. Thread an UNPLUGGED, UL-approved, 30 amp. Internal Ground
power cord, NEMA 14-30 type ST or SRDT, through Green Screw
the strain relief. (See Figure 2-10) Install
UL-approved
5. Disconnect the internal (BLACK) dryer harness strain relief here
ground wire from the (GREEN) ground screw next to
Terminal Screw
2
the terminal block. (See Figure 2-11) Recovery Slot
6. Attach the ground (GREEN) power cord wire to the
Figure 2-10.
cabinet with the ground (GREEN) screw. Tighten
the screw securely.
7. Move the internal dryer harness ground
(BLACK) wire to the terminal block and attach
it along with the neutral (WHITE) power cord
If a terminal screw falls during cord installation,
wire conductor to the center, SILVER colored
it can be retrieved in the terminal screw recovery
terminal on the terminal block. Tighten the
slot below the access panel.
screw securely.
8. Attach the RED and BLACK power cord Move internal ground (Black)
wire to neutral (Silver) Neutral terminal
conductors to the outer, BRASS colored
terminal for 4-wire system
terminals on the terminal block. Tighten both
screws securely.
Neutral
White wire

Green
ELECTRICAL SHOCK HAZARD ground screw
DO NOT MAKE A SHARP BEND OR CRIMP
WIRING/ CONDUCTOR AT CONNECTIONS.
9. Follow manufacturer’s guidelines for firmly
securing the strain relief and power cord. Green Black or Red
ground wire power wire
10. Reinstall the terminal block cover..

Black or Red
power wire

Figure 2-11.

2-10
Installation Information
Gas Supply Requirements Gas Connection

1. Installation MUST conform with local codes, or in the 1. Remove the shipping cap from gas pipe at the rear
absence of local codes, with the National Fuel Gas of the dryer.
Code, ANSI Z223.1 (latest edition). 2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
2. The gas supply line should be 1/2 inch (1.27cm) approved pipe from gas supply line to the 3/8 inch
pipe. (0.96 cm) pipe located on the back of the dryer. Use
a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm) reducer
for the connection. Apply an approved thread sealer
that is resistant to the corrosive action of liquefied
EXPLOSION HAZARD gases on all pipe connections. (See Figure 2-12)
UNCOATED COPPER TUBING WILL CORRODE
WHEN SUBJECTED TO NATURAL GAS,
CAUSING GAS LEAKS. USE ONLY BLACK IRON,
STAINLESS STEEL, OR PLASTIC
COATED BRASS PIPING FOR GAS SUPPLY.

3. If codes allow, flexible metal tubing may be used


to connect your dryer to the gas supply line. The
tubing MUST be constructed of stainless steel or
plastic-coated brass. Figure 2-12.
4. The gas supply line MUST have an individual 3. Open the shutoff valve in the gas supply line to
shutoff valve. allow gas to flow through the pipe. Wait a few
5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, minutes for gas to move through the gas line.
accessible for test gauge connection, MUST be
installed immediately upstream of the gas supply
connection to the dryer.
The supply line must be equipped with an
6. The dryer MUST be disconnected from the gas
approved manual shutoff valve. This valve
supply piping system during any pressure testing of
should be located in the same room as the dryer
the gas supply piping system at test pressures in
and should be in a location that allows ease of
excess of 1/2 psig (3.45 kPa). opening and closing. Do not block access to the
7. The dryer MUST be isolated from the gas supply gas shutoff valve.
piping system during any pressure testing of the
gas supply piping system at test pressures equal to to
dry
or less than 1/2 psig (3.45 kPa). er
8. Connections for the gas supply must comply with the
Standard for Connectors for Gas Appliances, ANSI
Z21.24.
fro
m
ga
ss
up
ply
EXPLOSION HAZARD
NEVER TEST FOR GAS LEAKS WITH AN OPEN Valve -
FLAME. Open position
Figure 2-13.
4. Check for gas system leaks with a manometer.
If a manometer is not available, test all
DO NOT connect the dryer to L.P. gas service
connections by brushing on a soapy water
without converting the gas valve. An L.P.
conversion kit must be installed by a qualified solution.
gas technician.

2-11
Installation Information
Water Connection
(Steam Model Only)
1. Turn off COLD water supply to washer,
2. Remove COLD inlet hose from COLD water supply
and inspect for rubber washer. Replace washer if it
is torn or worn out.
3. Momentarily turn on COLD supply and run some
water into a bucket or container to clear any
contaminants in the line.
4. Remove hose kit from dryer drum and inspect hose
couplings for proper placement of rubber washers.
(See Figure 2-14)
5. If your installation has room for the COLD water
supply to accept the “Y” connector directly, thread
the “Y” connector to the COLD water supply and
snug it by hand; then tighten it another 2/3 turn with
pliers.
Figure 2-14.

If you were able to install the “Y” connector


directly to the COLD water supply, please skip to
step 8.

6. If there is not room to install the “Y” connector


directly, thread the short extension hose on to the
COLD water supply and snug it by hand; then tighten
it another 2/3 turn with pliers.
7. Thread the “Y” connector to the short extension hose
and snug it by hand; then tighten it another 2/3 turn
with pliers.
8. Connect the COLD inlet hose for the washer to the
“Y” connector and snug it by hand; then tighten it
another 2/3 turn with pliers.
9. Connect the straight end of the long hose from the
kit to the other outlet on the “Y” connector and snug
it by hand. Connect the hose’s 90° coupling to the
brass water inlet on the back of the dryer and snug
it by hand. Tighten each connection of the dryer inlet
hose another 2/3 turn with pliers.
10. Turn on the water and check for leaks at all
connections.

2-12
Installation Information
General Installation
1. Connect exhaust duct to the outside exhaust
system. Use of a 4” (10.2 cm) clamp is
recommended to connect the dryer to the exhaust
vent system. Use metal foil tape to seal all other
joints. (See Figure 2-15)
2. Carefully slide the dryer to its final position. Adjust
one or more of the legs until the dryer is resting
solidly on all four legs. Place a level on top of the
dryer. The dryer MUST be level and resting solidly
on all four legs. Rock alternating corners to check
for stability. Remove and discard door tape. (See 4” Clamp
Figure 2-16)
Figure 2-15.

Be sure power is off at a circuit breaker/fuse


box before plugging power cord into an outlet.

3. Plug the power cord into a grounded outlet.


4. Turn on power at the circuit breaker/fuse box.
5. Perform the “Installation Cycle” to verify proper
installation.

On gas dryers, before the burner will light, it is


necessary for the gas line to be bled of air. If the
burner does not light within 45 seconds the first
time the dryer is turned on, the safety switch will Figure 2-16.
shut the burner off. If this happens, press cancel
and wait 5 minutes before making another attempt
to light.

2-13
Installation Information
Wave-Touch™ Installation Cycle IQ -Touch™ Installation Cycle
1. After plugging in the dryer the first time: wake up 1. Empty dryer’s drum and close door.
the dryer by pressing any button and then follow the 2. After you plug in the dryer the first time: wake up the
prompts on the LCD User Interface, including dryer by pressing any button, rotate cycle knob to
language selection. touch up cycle, press the start button and then the
2. The Installation Cycle will automatically test for cancel button.
correct cord connection (on electric models), 3. Wake up the dryer again by pressing any button,
presence of gas supply (on gas models) and free then immediately and simultaneously press and
flow of exhaust vent. At cycle completion, the hold both the sanitize and my favorite buttons for 5
LCD user interface may display INSTALL PASS!, seconds, or until the LCD display changes.
meaning the dryer is properly installed and ready 4. The LCD window will display INSTAL CYCLE
for use. If it prompts an action such as SERVICE and show estimated time of cycle completion.
CORD, NO GAS or Call Service 877-435-3287, Press the start button. The Installation Cycle will
review the installation steps and make the necessary automatically test for correct cord connection (on
corrections before attempting to use the dryer. electric models) and presence of gas supply (on
3. The dryer will exit the Installation Cycle and gas models). At cycle completion, the LCD window
return to normal operation the next time the may display INSTAL PASS!, meaning the dryer is
dryer is used. properly installed and ready for use. If it prompts an
action such as SERVICE CORD, NO GAS or
Call Service 877-435-3287, review the installation
steps and make the necessary corrections before
attempting to use the dryer.
5. The washer will exit the Installation Cycle and
return to normal operation the next time the washer
is used.

Dryer will stay awake for 3 minutes after the


Installation Cycle. If you wish to immediately run
the dryer through a drying cycle, press the cancel
button to put the unit to sleep and then rewake
it immediately, to continue the normal operating
mode.

2-14
Installation Information
Reversing Door
Preparing to Reverse Door Swing
1. Be sure you have adequate swing area before
reversing door.
2. You will need a screw driver with a #2 square bit.
3. Protect flat work surface, such as top of washer or
floor near washer, with a soft cloth or towel.
4. Be sure washer is unplugged from power source.

Removing Trim Ring Figure 2-17.


1. Open the door to a 90 degree angle.
2. Remove and save the trim plug and long, course-
thread, panhead screw. (See Figure 2-17)
3. Close the door.
4. Rotate the door trim approximately ¾” counter-clock
wise and pull it away from the front of the door.
(See Figure 2-18)

Removing Door from Hinge

1. Reopen door to 90 degree angle.


2. Remove 4 long, course-thread, counter-sunk hinge Figure 2-18.
screws from door. (See Figure 2-19)
3. While supporting the weight of the door with both
hands, separate the door from the hinge.
(See Figure 2-20)
4. Gently place the door face down on a flat, covered
work surface.

Figure 2-19.

Figure 2-20.

2-15
Installation Information
Removing Hinge from Front Removing Door Lock from Front
Panel Panel
1. With the hinge in open position, remove 2 short, 1. Remove 2 short, course-thread, panhead
course-thread, panhead screws on hinge plate. screws from the door lock. (See Figure 2-24)
(See Figure 2-21) 2. Slide the lock toward the outer edge of the
2. Remove 3 short, fine-thread, counter-sunk screws in front panel. Pivot the lock slightly outward
hinge side. (See Figure 2-22) while slowly pulling it through opening to
3. Slide the hinge toward the center of the front panel, expose the attached harness.
and then pivot the hinge inward while slowly pulling (See Figure 2-25)
it away from the front panel to expose the attached 3. Release the harness from the terminal with
harness. the small lever on back of the lock. Separate
4. Lift up on the tab and the release harness from the the harness from the lock, allowing the harness to
retainer, allowing the harness to lay outside the front lay outside the front panel. (See Figure 2-26)
panel. (See Figure 2-23)

Figure 2-24.

Figure 2-21.

Figure 2-25.

Figure 2-22.

Figure 2-23. Figure 2-26.

2-16
Installation Information
Reattaching Door Lock to Font Reattaching Hinge to Front Panel
Panel 1. Rotate the hinge and move it to the opposite
opening.
1. Rotate the door lock and move it to the opposite
opening. 2. Connect the harness to the hinge retainer by
inserting it in the retention terminal and gently
2. Connect the harness to the door lock by inserting it
pushing until you hear the fastening tab click.
in the terminal and firmly pushing it in place. (See
(See Figure 2-30)
Figure 2-27)
3. Gently pull on the harness to be sure it is secure.
3. Insert the harness connection through the front panel
first, and then pivot the lock until it is flush. Slide the 4. Use the side locating pins to align the hinge and
lock toward the center of the front panel until the install 1 short, fine-thread, counter-sunk screw in the
screw holes line up. (See Figure 2-28) center hole of hinge side. (See Figure 2-31)
4. Secure the lock with 2 short, course-thread, panhead 5. Install the other 2 short, fine-thread, countersunk
screws. (See Figure 2-29) screws in upper and lower holes of hinge side.
6. Install 2 short, course-thread, panhead screws
through hinge plate. (See Figure 2-32)

Figure 2-27.

Figure 2-30.

Figure 2-28.

Figure 2-31.

Figure 2-29. Figure 2-32.

2-17
Installation Information
Removing Striker Plate Removing Latch Indicator
1. Remove 2 long, course-thread, counter-sunk screws 1. Grasp the indicator on the latch side between finger
and striker plate. (See Figure 2-33) and thumb and rock it upward, pivoting away from
2. Set the striker plate to the side for later. the center of the glass. (See Figure 2-34)
2. Gently push the indicator toward the center of the
lens to release the tab.
3. Rock the tab upward. (See Figure 2-35)
4. Pull the indicator out and set it aside.
(See Figure 2-36)

Figure 2-33.

Figure 2-34.

Figure 2-35.

Figure 2-36.

2-18
Installation Information
Removing Hole Plug Reinserting Latch Indicator
1. Grasp the hole plug between finger and thumb and 1. Rotate the latch indicator and move it to the
rock it upward, pivoting it away from the center of the opposite hole in the door.
glass, releasing the tab. (See Figure 2-37) 2. Grasp the indicator between finger and thumb and
2. Connect the harness to the door lock by inserting it slide it through the opening. (See Figure 2-39)
in the terminal and firmly pushing it in place. 3. Gently push the indicator toward the center of the
3. Insert the harness connection through the front panel glass and pivot the tab downward into the retaining
first, and then pivot the lock until it is flush. Slide the slot. (See Figure 2-40)
lock toward the center of the front panel until the 4. Pivot the indicator downward toward the center of
screw holes line up. (See Figure 2-38) the glass until it is in place.
4. Secure the lock with 2 short, course-thread,
panhead screws.

Figure 2-39.

Figure 2-37.

Figure 2-40.
Figure 2-38.

2-19
Installation Information
Reattaching Striker Plate Reattaching Door Assembly
1. Rotate the striker plate and move it to the opposite 1. Open the hinge to a 90 degree angle.
side of door above the indicator. 2. Install the door onto the hinge locating pins.
2. Reattach with 2 long, course-thread, counter-sunk (See Figure 2-43)
screws. (See Figure 2-41) 3. Secure the door with 4 long, course-thread,
counter-sunk screws. (See Figure 2-44)
4. Close the door and test the operation of the latch.

Figure 2-41.

Figure 2-43.
Reinserting Hole Plug
1. Rotate the hole plug and move it to the opposite hole
in the door.
2. Grasp the hole plug between finger and thumb and
insert the tab into the retaining slot.
(See Figure 2-42)
3. Pivot the hole plug downward toward the center of
the glass until it is in place.

Figure 2-44.

Figure 2-42.

2-20
Installation Information
Reversing Trim Ring Reinstalling Trim Plug
1. Trim ring orientation is marked on the back. 1. Open the door to a 90 degree angle.
2. Remove the trim ring cover plate. To remove the 2. Install the trim plug with 1 long, course thread,
cover plate from the right, pivot point is up. To panhead screw. (See Figure 2-47)
remove the cover plate from the left, pivot point is 3. Plug in washer and continue operation.
down. (See Figure 2-45)

UP

Figure 2-45.
Figure 2-47.

Reinstalling Trim Ring


1. Close the door.
2. Orient the trim so 12 position is approximately
¾” to the left of top center. The opening in the
trim ring should be on the hinge side.
3. Insert the trim ring in the slots and rotate it
clockwise approximately ¾”. (See Figure 2-46)

Figure 2-46.

2-21
Installation Information
Accessories
Matching Storage Pedestal
Island White Pedestal - P/N EPWD15IW
Mediterranean Blue - P/N EPWD15MB
Silver Sands Pedestal - P/N EPWD15SS Storage Pedestal
Turquoise Sky Pedestal - P/N EPWD15TS

A storage pedestal accessory, specifically designed for


this washer may be used to elevate the dryer for ease
of use. This pedestal will add about 15” (38.1cm) to the
height of your unit for a total height of 53” (134.62 cm).

Figure 2-48.
Dryer Stacking Instructions
A
Kit Components: (See Figure 2-49)
• 1 Dryer Stacking Instructions.
A. 1 Front bracket with adhesive strip.
B
IMPORTANT - DO NOT remove RED backing from
adhesive strip until instructed to do so.
B. 2 rear brackets.
C
C. 2 strips of self-adhesive protective film.
D. (6) #10 (16 x 3.75) screws.
D
Preparing to Stack

1. Be sure there is adequate space to stack dryer on


top of washer. Figure 2-49.
2. You will need a screw driver with a #2 square bit,
isopropyl alcohol and a clean cloth.
3. Read washer and dryer installation instructions
packed with each appliance prior to stacking.
4. Be sure washer and dryer are both unplugged.

Preparing Dryer for Stacking

1. If already installed, disconnect dryer from electrical


and gas connections and exhaust venting. On
models with Steam Option, disconnect water supply
to dryer. Figure 2-50.
2. Protect floor with cardboard or other covering and
carefully tip dryer onto its back. (See Figure 2-50)
3. Remove adjustable leveling legs and save for future
use.
4. Attach front stacking bracket to dryer front with (2) -
#10 screws. (See Figure 2-51)
5. Carefully return dryer to upright position.

Do not remove red backing from Adhesive strip yet!


Do not remove any existing screws from front panel.
Figure 2-51.

2-22
Installation Information
Prepare Top Surface of Washer: Stacking Dryer
1. Wipe front portion of top with isopropyl alcohol and a 1. When washer is within 4 feet of its final installation
clean cloth. (See Figure 2-52) site, electrical and water connections have been
2. Carefully remove BLUE backing from clear self completed, and washer is level, have two or more
adhesive strips. Apply to each side edge of the people lift the dryer onto washer.
washer top. (See Figure 2-53) 2. Hold the front of the dryer up slightly carefully slide
3. Attach each rear bracket to washer top with two (2) the dryer back.
#10 screws. (See Figure 2-54) 3. Slide hook tabs on rear brackets into slots in back
sheet of dryer. Dryer will be approximately ¼” left of
center. Continue sliding dryer back until tabs are fully
engaged. (See Figure 2-55)
4. Slide dryer approximately ¼” to the right, centering
it on washer and hooking rear bracket tabs into slots
on back.
5. Lift front of dryer and remove RED backing from
adhesive strip on front bracket. (See Figure 2-56)
6. Gently lower dryer to adhere front bracket to washer
top. Align dryer side panel to washer side panel as
Figure 2-52. you lower dryer.
7. Refer to installation instructions to connect dryer
venting, power and accessories.

Figure 2-53.

Figure 2-55.

Figure 2-54.

Figure 2-56.

2-23
Installation Information
Removing Stacked Dryer
1. Disconnect dryer from electrical and gas
connections and exhaust venting. On models with
Steam Option, disconnect water supply to dryer.
2. Disconnect washer from electrical source.
3. With #2 square bit screwdriver, remove two front
bracket screws and save for reinstallation. (See
Figure 2-57)
4. Slide the dryer approximately ¼” to the left to
disengage dryer from rear brackets.
5. Support the front of the dryer, clearing the front Figure 2-57.
bracket, while sliding the dryer forward. Have two or
more people lift the dryer off the washer and gently
place it on the floor.

If laundry appliances must be moved, front and


rear mounting brackets may remain attached to
the washer top until the dryer is restacked. To
permanently unstack the units and remove the
front bracket, use a 24” piece of monofilament
(fishing) line to carefully saw back and forth under
the adhesive strip. Remove residue with a general
adhesive remover.

2-24
Electronic Control
Control Panel (User Interface Layout) Wave-Touch™
Cycle Selector User Interface
Display

Temperature Extended Tumble


Dryness Level Options Scroll
Figure 3-1. Wave-Touch™ Control Panel

Selecting the Appropriate Cycle and Settings Overview


Turn the cycle selector knob in either direction to select the cycle desired. The icon for that cycle will be illuminated
and if the cycle description feature is turned on, the cycle and estimated cycle time are displayed on the User Interface
screen for 5 seconds. Press any key to advance the User Interface to select settings and options.
Press any key or the User Interface screen will automatically advance after 5 seconds and display the preset drying
temperature, dryness level (Auto Dry) or drying time (Time Dry), extended tumble time, and options for the cycle
selected will be displayed.
To change the settings, press the temp, dryness level (Auto Dry) or drying time (Time Dry) and extended tumble
buttons to scroll to the desired settings. Press the scroll up or scroll down buttons under options to scroll through the
options menu. Press the select button to add or delete options. The estimated cycle time will be displayed at the top
of the screens.
Adjustments to a cycle will be remembered and recalled each time that cycle is selected in the future. To return to the
factory default settings, select RESET in set prefs under the options scroll buttons.

Demo Mode
Demo Mode will standby for 10 minutes then perform an LED on/off sequence for 3 minutes. During the standby
sequence the drum light and start button will be activated. The controls will be fully functional during Demo Mode
with abbreviated cycles lasting about 1 minute. Some features will be deactivated during Demo Mode for safety
purposes. When the units are in Demo Mode the text “DEMO MODE” will be displayed in the LCD screen. Demo
mode will be saved if the units are unplugged or if there is a power outage. To deactivate Demo Mode repeat steps
1-3 below.
NOTE: Set the controls to the desired language in the SET PREFS menu. After the unit has been set to DEMO
mode the language can not be changed.
1. Turn the cycle selector knob to TIME DRY cycle, press the START button then the CANCEL button.
2. Activate the controls by turning the cycle selector knob and turn to TIME DRY cycle.
3. Press and hold CANCEL button and EXTENDED TUMBLE (Third button from the left) for 3 seconds.
4. DEMO MODE instructions have to be completed by 7 seconds of the control activation.
5. Press the CANCEL button to begin DEMO MODE.
6. To deactivate DEMO MODE repeat steps 1 – 3.

3-1
Electronic Control
Wave-Touch™ Dryer Options Chart

3-2
Electronic Control
Wave-Touch™ Dryer Options Chart Steam Model)

3-3
Electronic Control
Control Panel (User Interface Layout) IQ-Touch™
User Interface
Display
Cycle Selector

Temperature Scroll Dryness Scroll Options


Figure 3-2. IQ-Touch™ Control Panel

Selecting the Appropriate Cycle and Settings Overview


Turn the cycle selector knob in either direction to select the cycle desired. The indicator for that cycle will
be illuminated.
A suitable drying temperature, dryness level and options will automatically be indicated for the cycle
selected.
To change settings, press the temperature, dryness and options buttons to scroll to the desired settings.
To select or delete an option, press the button for that option. The indicator will light when the option has
been selected. It will no longer be lighted when the option has been deleted.
Adjustments to a cycle will be remembered and recalled each time that cycle is selected in the future.
To return to factory settings, press the temperature and dryness buttons at the same time and hold for 5
seconds.

Demo Mode
Demo Mode will standby for 10 minutes then perform an LED on/off sequence for 3 minutes. During the
standby sequence the drum light and start button will be activated. The controls will be fully functional dur-
ing Demo Mode with abbreviated cycles lasting about 1 minute. Some features will be deactivated during
Demo Mode for safety purposes. When the units are in Demo Mode the text “DEMO MODE” will be dis-
played in the LCD screen. Demo mode will be saved if the units are unplugged or if there is a power out-
age. To deactivate Demo Mode repeat steps 1-3 below.
1. Turn the cycle selector knob to TIME DRY cycle, press the START button then the CANCEL button.
2. Activate the controls by turning the cycle selector knob and turn to TIME DRY cycle.
3. Press and hold CANCEL button and CTRL LOCK button for 3 seconds
4. DEMO MODE instructions have to be completed by 7 seconds of the control activation.
5. Press the CANCEL button to begin DEMO MODE.
6. To deactivate DEMO MODE repeat steps 1 – 3.

3-4
Electronic Control
IQ-Touch™ Dryer Options Chart

3-5
Electronic Control
Cycle Selection

The following cycle descriptions are for the Wave


Touch™ and IQ Touch™ Dryers.
The IQ Touch ™ models do not feature the steam
option and the active wear preset.

Turn the cycle selector in either direction to the cycle


desired. The icon for that cycle will be illuminated. Press
on the cycle selector knob to extend it or return it flush to
the console.
To change the selection after the cycle begins, press
cancel before making another choice. Just turning the
cycle selector knob to another selection will not change
the cycle.

Auto Dry Cycles


Moisture sensing bars at the back of the dryer drum
sense the moisture level of the load as it tumbles
through the heated air. With Auto Dry cycles, the load
will automatically be dried at the selected temperature to
the desired dryness level. When the load has reached
the selected dryness level, it will continue to tumble,
unheated, during a cool down period.
Drying time varies depending on size and dampness of
load and fabric type. If the load is too small or almost
dry, the moisture sensing bars may not detect enough
moisture to continue the cycle and the cycle may end
after a few minutes. If this occurs, then select the time
dry cycle to dry such loads.

Normal
Select this cycle to dry everyday fabrics including
cottons and sheets with high temp, med high temp or
medium temp heat. All dryness levels except maximum
dry and all options including sanitize are available with
this Auto Dry cycle. If equipped with Perfect Steam™,
the add steam option is also available with this cycle.

Towels
Select this cycle to dry heavy loads such as towels
and bath mats with maximum temp, high temp or med
high temp heat. The maximum dry, more dry and normal
dry dryness levels and the gentle tumble and sanitize
options are available with this Auto Dry cycle.

3-6
Electronic Control
Mixed Load Time Dry Cycles
Select this cycle to dry loads containing a mix of fabrics
with med high temp, medium temp, or med low temp
heat. All dryness levels except maximum dry and all
FIRE HAZARD
options except sanitize are available with this Auto Dry
cycle. If equipped with Perfect Steam™, the add steam TO AVOID FIRE HAZARD, DO NOT USE HEAT
option is also available with this cycle. TO DRY ITEMS CONTAINING FEATHERS OR
DOWN, FOAM RUBBER, PLASTICS SIMILARLY
Heavy Duty TEXTURED, RUBBER-LIKE MATERIALS. USE
THE TIME DRY CYCLE AND THE AIR (NO HEAT)
Select this cycle to dry durable fabrics such as jeans and
SETTING.
overalls with maximum temp, high temp, or med high
temp heat. All dryness levels except damp dry and all
options including sanitize are available with this Auto Dry Time Dry
cycle.
To manually select the drying time for any load, turn
Bulky/ Bedding the cycle selector knob to time dry and press the drying
time button to select up to 90 minutes of drying time in
Select this cycle to dry bedding and bulky items such as 15-minute increments. Select any drying temperature.
comforters, blankets, sleeping bags and parkas with med Dryness levels are not selectable with Time Dry cycles.
high temp, medium temp, or med low temp heat. Normal The extended tumble, wrinkle release, delicate heat
dry and less dry dryness levels and all options except and shrink guard options are available with the time dry
sanitize are available with this Auto Dry cycle. cycle.
Casual Fast Dry
Select this cycle to dry cottons and blends with a no-iron Select this cycle to quickly dry small loads in 18 minutes
finish using med high temp, medium temp, or med low with maximum temp, high temp, or med high temp heat.
temp heat. Normal dry, less dry, and damp dry dryness No options are available with this Time Dry cycle.
levels and all options except sanitize are available with
this Auto Dry cycle. If equipped with Perfect Steam™, Touch Up (non-steam models only)
the add steam option is also available with this cycle.
Select this cycle to remove wrinkles from clean, dry
Active Wear items that may have been left in the dryer, stored in
crowded closets or drawers or unpacked from luggage.
Select this cycle to dry lightweight synthetic athletic The load will tumble for 15 minutes on low temp heat.
apparel including stretch fabrics with medium temp, med The gentle tumble option is available with this Time Dry
low temp or low temp heat. Normal dry, less dry, and cycle.
damp dry dryness levels and all options except sanitize
are available with this Auto Dry cycle. Perfect Steam (steam models only)
Delicate Select this cycle to refresh fabrics, remove odors and
reduce static by injecting the perfect amount of cold
Select this cycle to dry knits and delicates with med low water into clothing that has been left in the dryer, stored
temp or low temp heat. Normal dry, less dry, and damp in crowded closets, drawers, or unpacked luggage. The
dry dryness levels and all options except sanitize are load will tumble for 15 minutes on low temp heat while
available with this Auto Dry cycle. cold water is injected into the drum. The gentle tumble
option is available with this Time Dry cycle.

3-7
Electronic Control
My Favorites (Wave Touch™) To select a user if a user’s name is not displayed when
the washer is turned on:
To select one of your 3 favorite cycles:
1. Press the options buttons to scroll to set prefs and
• Turn the cycle selector knob to my favorites. then press the select button.
• Press the button corresponding to the favorite 2. If necessary, press the options buttons to scroll to
cycle desired. The custom cycle, settings, and CUSTOM MODE and then press the select button.
options saved will automatically be displayed.
3. Press the button corresponding to the user’s name.
• Press the start button to begin the cycle.
4. The icon for the last cycle run will light up.
For example, to select your my shirts cycle, turn the
5. Turn the cycle selector knob to my favorites.
cycle selector knob to my favorites. Press the
button corresponding to my shirts, and then press start. 6. Select one of the 3 customized cycles by pressing
the corresponding button.
If more than one user has been entered in
7. Press the start button.
CUSTOM MODE:
1. The current user’s name will be displayed when the
washer is turned on if CUSTOM MODE is on.
2. Press the button under OK to continue using that
user’s favorite cycles.
3. The icon for the last cycle run will light up.
4. Turn the cycle selector knob to my favorites.
5. Select one of the 3 customized cycles by pressing
the corresponding button.
6. Press the start button.

To change users:
1. Press the select button when the washer turns on
and shows the current user’s name.
2. Press the button under change users.
3. Select another user’s name.
4. Press the button under EXIT.
5. The icon for the last cycle run will light up.
6. Turn the cycle selector knob to my favorites.
7. Select one of the 3 customized cycles by pressing
the corresponding button.
8. Press the start button.

3-8
Electronic Control
Drying Temperature
Auto Dry
The appropriate drying temperature will automatically be
indicated for the cycle selected.
To change the preset temperature, press temperature
button to scroll to the desired setting.
To protect fabrics, not all temperatures are available with
every cycle. If a temperature is not appropriate for the
cycle, it will not be displayed.
The temperature selected for the cycle will be
remembered each time that cycle is selected in the
future.

Maximum Temp
Recommended to use with the sanitize option for towels
and heavy duty loads.

High Temp
Recommended for durable fabrics.

Med High Temp


Recommended for most cotton fabrics.

Medium Temp
Recommended for wrinkle free, easy care lightweight
fabrics and bulky loads.

Med Low Temp


Recommended for knits.

Low Temp
Recommended for delicate fabrics.

Air Fluff Temp


This setting (no heat) should only be used with a time
dry cycle to dry items containing feathers, down, foam
rubber, plastics or rubber-like materials;to refresh
clothing, stuffed animals, pillows or blankets; and to dust
draperies.

Time Dry
Press the drying time button to select up to 90 minutes
of drying time in 15-minute increments. This setting is
only available with the time dry cycle.

3-9
Electronic Control
Options
Suitable options will automatically be indicated when the
cycle is selected.
To add options, press the corresponding options buttons
to illuminate the selections desired. To delete options,
press the options buttons again and the indicator lights
will turn off. Not all options are available with every
cycle. The indicator will not light if the option is not
available with that Cycle.
All options selected for the cycle, except sanitize, will be
remembered and recalled each time that cycle is
selected in the future. To prevent unintentional and
accidental exposure of delicate material to sanitize heat,
the sanitize option will not be remembered and must be
reselected each time.

Add Steam (steam models only)


The add steam option injects steam into the clothing
prior to cool down to reduce wrinkling, ironing and static
cling.

Extended Tumble
Select the extended tumble option if the dried load might
not be removed promptly at the end of the cycle. The
dry load will tumble continuously without heat for 30
minutes. “Ext. Tumble” will be displayed and a chime
will sound every 5 minutes to remind you to remove the
dried load. The wrinkle release option can be selected
with extended tumble to increase the amount of time the
load will tumble without heat.

Wrinkle Release (IQ Touch)


Select the wrinkle release option if the dried load might
not be removed promptly at the end of the cycle. To
help prevent wrinkles, the dry load will intermittently tum-
ble for a total of 45 minutes. “Wrinkle Rel.” will be dis-
played and a chime will sound every 5 minutes to remind
you to remove the dried load.
The extended tumble option can be selected with wrinkle
release to add another 30 minutes of tumbling without
heat.

Wrinkle Release (Wave Touch)


The wrinkle release option helps prevent wrinkles and
tangling by alternately tumbling the load without heat
for 5 minutes in a clockwise direction, then 5 minutes in
a counterclockwise direction, for a total of 45 minutes.
A signal will sound every 5 minutes to remind you to
Add steam option available on Steam Model only.
remove the dry load at any time.

3-10
Electronic Control
Gentle Tumble
The gentle tumble option uses reverse tumble action
during cool down to reduce tangling and wrinkling.

Delicate Heat
Select this option to protect a load from excessive heat.
The drying temperature will be gradually reduced as the
load dries.

Sanitize
Select this option for loads that may contain harmful
bacteria. An extended drying time at high heat will kill
99.9% of bacteria with no carryover of bacteria between
loads. Check fabric care labels to prevent damage
caused by high heat.

Chime
Select this option to add a chime to the end of the cycle,
to indicate when load is damp in the damp alert option,
and as a reminder to remove the load during extended
tumble and wrinkle release. Press the chime button to
select volume level desired or to turn off the signal.

Damp Alert
For loads that contain some items you plan to hang dry,
flat dry or iron, add the damp alert option to any Auto Dry
cycle. A signal will sound when the load has reached
the damp dryness level to remind you to remove those
items to hang dry, dry flat or iron dry. Open the door,
remove those items, close the door and press the start
button to continue drying the remaining items.

Shrink Guard
The shrink guard option reduces the initial drying
temperature and gradually lowers drying temperature
during the cycle to protect fabrics from shrinking.

Add steam option available on Steam Model only.

3-11
Electronic Control
User Interface Features
Save as Favorite
The save as favorite feature allows you to
personalize up to 3 custom cycles for each custom user.

Set Prefs
The set prefs feature allows you to personalize cycles,
hide cycle descriptions, select the language, volume,
brightness and contrast of the display, reset settings, and
run the installation cycle. LIST OF SAVED FAVORITES

User Guides
Scroll through this option for the CYCLES GUIDE,
SETTINGS GUIDE, OPTIONS GUIDE, and SET PREFS
GUIDE for descriptions of the cycles, water tempera-
tures, spin speeds, soil levels, cycle options and features
for user preferences. CUSTOM MODE

Control Lock (WaveTouch™) INSTALL CYCLE


To lock the controls between cycles, scroll to the control
lock feature press select and “CONTROL LOCK OFF - RESET
PRESS SELECT TO LOCK THE CONTROL PANEL”
will be displayed. Press the select button to lock the con- CONTRAST
trols. To unlock the controls, press and hold select again
for 3 seconds. Use this feature to reduce the likelihood of BRIGHTNESS
accidental operation by children.
VOLUME
Control Lock (IQTouch™)
LANGUAGE
To lock the controls between cycles, press and hold the
control lock button for 5 seconds. Repeat to unlock the
CYCLE DESC ON
controls when you are ready to operate the dryer.

CYCLES GUIDE

SETTINGS GUIDE

OPTIONS GUIDE

SET PREFS GUIDE

CONTROL LOCK ON

CONTROL LOCK OFF

3-12
Electronic Control
Save as Favorite
The save as favorite feature allows you to personalize up
to 3 custom cycles for each custom user.
1. Select a cycle, drying temperature, dryness level
(Auto Dry) or drying time (Time Dry), extended
tumble time and other options desired.
2. Use the scroll up or scroll down button until you
reach save as favorite.
3. Press the select button to enter the favorite cycle
choice screen.
4. Choose 1 of the 3 buttons for naming cycle.
5. See below for naming your favorite cycle.
For example, to customize the normal cycle for shirt
loads using med high drying temperature, normal dry
dryness level and 10 minutes of extended tumble:
1. Turn the cycle selector knob to normal.
2. Press the temp button to select medium temp.
3. Press the dryness level button to select normal
dryness.
4. Press the extended tumble button to select 10
minutes.
5. Press the scroll up or scroll down button until you
reach save as favorite.
6. Press the select button to enter the favorite cycle
choice screen.
7. Press the button under my favorite 1.

To name the customized cycle for shirts, press my


favorite 1.
Press the button under ABC to name the favorite cycle
alphabetically. Use the button under 1A# to add numbers,
foreign language characters or symbols to the name.
Rotate the cycle selector knob in either direction to select
the letters S-H-I-R-T-S, pausing after each character to
let the cursor advance. Press the button under DELETE
to erase incorrect entries. There is a blank character
between Z and A for inserting spaces in your custom
name. Pause momentarily on this character as you
would to insert any other character, then continue. Press
select to save the favorite cycle name. Repeat the steps
to customize 2 other cycles as my favorite 2 and my
favorite 3. Any of the favorite cycle names can be
changed in the future by turning the cycle selector knob
to my favorites and pressing the button under EDIT
NAMES.

3-13
Electronic Control
Setting Preferences
Custom Mode
CUSTOM MODE allows up to 3 household members to
personalize up to 3 favorite cycles each.
To enter custom users and personalize favorite cycles:
1. Use the scroll up or scroll down buttons until you
reach set prefs. Press the select button to enter the
preference menu.
2. Press select again to enter CUSTOM MODE.
3. Press the button for user 1, user 2 or user 3.
4. Press select.

Press the button under ABC to name the favorite cycle


alphabetically. Use button under 1A# to add numbers,
foreign language characters or symbols to the name.
Rotate the cycle selector knob in either direction to
select the characters in the name, pausing after each
character to let the cursor advance. Press button under
DELETE to erase incorrect entries. There is a blank
character between Z and A for inserting spaces in your
custom name. Pause momentarily on this character as
you would to insert any other character, then continue.
When the name has been entered, press select to save
the name.
To edit names while in CUSTOM MODE, turn the dryer
off by pressing cancel. Press any other button to wake
the dryer up. Screen will display “TO CHANGE OR
TURN OFF USERS PRESS SELECT”. You must press
select within 5 seconds or dryer will return to normal
operation with previous user selected. After pressing
select you have the choice of change users, edit names,
turn off or EXIT. Make your selection and follow the
directions displayed.
Each custom user may select up to 3 favorite cycles.
The washer will remember cycle settings, options,
preferences, etc. for each user.

3-14
Electronic Control
Install Cycle (WaveTouch™)
1. After plugging in the dryer the first time: wake up
The INSTALL CYCLE is prompted automatically only
the dryer by pressing any button and then follow the
once when the dryer is turned on the first time at the
prompts on the LCD User Interface, including
end of installation. After that, if you wish to run a
language selection.
subsequent INSTALL CYCLE when moving the dryer
2. The Installation Cycle will automatically test for or modifying your installation, you may perform your
correct cord connection (on electric models), own INSTALL CYCLE by selecting it in the set prefs
presence of gas supply (on gas models) and free feature and then following the screen prompts.
flow of exhaust vent. At cycle completion, the
LCD user interface may display INSTALL PASS!,
meaning the dryer is properly installed and ready
for use. If it prompts an action such as SERVICE
CORD, NO GAS or Call Service 877-435-3287,
review the installation steps and make the
necessary corrections before attempting to use the
dryer.
3. The dryer will exit the Installation Cycle and return to
normal operation the next time the dryer is used.

Install Cycle (IQ Touch™)


1. Empty dryer’s drum and close door. Dryer will stay awake for 3 minutes after the
2. After you plug in the dryer the first time: wake up Installation Cycle. If you wish to immediately run the
the dryer by pressing any button, rotate cycle knob dryer through a drying cycle, press the cancel button
to touch up cycle, press the start button and then to put the unit to sleep and then rewake it immedi-
the cancel button. ately, to continue the normal operating mode.
3. Wake up the dryer again by pressing any button,
then immediately and simultaneously press and
hold both the sanitize and my favorite buttons for 5
seconds, or until the LCD display changes. The errors may result from the following
4. The LCD window will display INSTAL CYCLE conditions:
and show estimated time of cycle completion. • SERVICE CORD error (electric dryer)—The power
Press the start button. The Installation Cycle will supply cord has been installed improperly or the house
automatically test for correct cord connection (on wiring to the receptacle is incorrect.
electric models) and presence of gas supply (on • NO GAS error (gas dryer)—There is no connection
gas models). At cycle completion, the LCD window between the dryer and the gas line or the valve is closed.
may display INSTAL PASS!, meaning the dryer is
properly installed and ready for use. If it prompts • CALL SERVICE—Troubleshoot and repair as needed.
Repeat the INSTALL CYCLE when corrections are
an action such as SERVICE CORD, NO GAS or
completed.
Call Service 877-435-3287, review the installation
steps and make the necessary corrections before
attempting to use the dryer.
5. The washer will exit the Installation Cycle and
return to normal operation the next time the
washer is used.

3-15
Electronic Control
Reset (WaveTouch™)
Press the buttons indicated to restore only cycle settings,
reset only factory preferences (users, language, bright-
ness, volume, etc.) or restore all factory defaults (both
cycle settings and factory preferences). Press the button
under EXIT to return to normal operation or press the
cancel button to turn the dryer off without making any
changes. If you do not make a selection within 30 sec-
onds the dryer will return to normal operation without any
changes. If you reset all settings, INSTALL CYCLE will
be displayed as though the dryer were just turned on for
the first time. Press the button under CANCEL if you do
not wish to rerun the INSTALL CYCLE.

Reset (IQTouch™)
To return to factory settings, press the temperature
and dryness buttons at the same time and hold for 5
seconds.

Contrast
Press the button beneath plus (+) or minus (-) symbols to
increase or decrease the contrast of the display. Press
select to accept the change or press the button under
EXIT to return to normal operation without any changes.

3-16
Electronic Control
Brightness
Press the button beneath the plus (+) or minus (-)
symbols to increase or decrease the brightness of the
display. Press select to accept the change or press the
button under EXIT to return to normal operation without
any changes.

Volume
Press the button beneath the plus (+) or minus (-)
symbols to increase or decrease the volume of the
chime. Press select to accept the change or press the
button under EXIT to return to normal operation without
any changes.

Language
Select English, French or Spanish for the display
language.

Cycle Description
The name, an icon and a brief description are displayed
for each cycle. To delete the display, press select. To
restore the display, press select and “CYCLE DESC
ON - PRESS SELECT TO TURN OFF” will appear in the
LCD User Interface.

Status Display
The estimated total cycle time will be displayed when the
cycle is selected. The estimated remaining cycle time is
displayed during the cycle.

Drum Light
The drum light will come on whenever the door is
opened to illuminate the drum during loading and
unloading. Closing the door turns off the light. The
drum light will automatically turn off if the door is left
open more than 3 minutes.
To activate the drum light during a cycle, press the
button under LIGHT. The light will stay on during the
cycle for 3 minutes. To turn it off, press the button under
LIGHT again.

3-17
Electronic Control
Diagnostics and Error Codes
Acronyms:
MB – Main Board (Board located inside machine on right side just behind control panel.)
MC – Motor Control
UI – User interface board (board located inside the front control panel)
DL – Door Lock

Reading Error Codes

1. Wake the dryer up by pressing any button (except the cancel button).
2. Press and hold the “CANCEL” and “START/ PAUSE” buttons simultaneously for 6 seconds. The failure code will
appear in the display as an E followed by two numbers.
NOTE: E00 means no failure code experienced.
3. To view the last 5 error codes recorded, refer to the Diagnostic Mode listed below.
4. Troubleshoot problem by using the chart on page 3-20.

To Clear Latest Stored Error Code

Press the “CANCEL” button to enter standby mode and enable diagnostic entry.
1. Within 10 seconds after pressing “CANCEL”, press any button to wake up the control.

2. Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the “CANCEL” and the
far left button under the display simultaneously for 3 seconds to enter the Diagnostic Mode.
NOTE: To save time at wake up, the welcome screen can be bypassed by turning the selector knob.
3. Turn the program knob counter clockwise 9 turns (clicks) from the Start Position. The control will signal the last 5
error codes with E00 meaning no error experienced.
4. Press and hold the far left key under the display and “CANCEL” buttons simultaneously for 3 seconds. The
code(s) will be cleared.
5. To return the washer to normal operation.
a) Unplug the power cord, wait 5-8 seconds, then reconnect the power cord OR
b) Turn the program knob clockwise 2 turns (clicks) back to the Start Position (LEDs are flashing).
Press the “CANCEL” and far left button under the display until the LEDs stop flashing.

Exiting Diagnostic Mode

To return the washer to normal operation:


1. Unplug the power cord, wait 5-8 seconds, then reconnect the power cord OR
2. Turn the program knob clockwise back to the Start Position. Press the “CANCEL” and far left button under the
display until the LEDs stop flashing.

3-18
Electronic Control
Diagnostic Mode
To Start the Diagnostic Mode

1. Press the “CANCEL” button to enter standby mode and enable diagnostic entry.
2. Within 10 seconds after pressing “CANCEL”, press any button to wake up the control.
3. Within 5 seconds of wake up, turn the selector knob to the far left cycle and press and hold the “CANCEL” and the
far left button under the display simultaneously for 3 seconds to enter the Diagnostic Mode.
NOTE: To save time at wake up, the welcome screen can be bypassed by turning the selector knob.
4. Upon entering Diagnostic Mode, all lights should flash for IQ Touch™ models and all lights on for the Wave
Touch™ models.
5. The following steps can be cycled through by turning the selector knob clockwise:

Diagnostic Mode
Selector Test Activated Component
Position Electric Gas Operator Check LCD row LCD digits

0 Lights / Buttons test


1 Motor Counter-Clockwise Check Motor function. Look for Drum “MOTOR
(CCW) rotation in counter-clockwise direction. CCW”
2 Check moisture reading. Place fingers “MOIST. “1111” if Contact
Contact Sensor across Contact Sensor and look for digit BARS” Sensor open circuit;
display to change from “1111” to “8888” ”8888” if Contact
Sensor short circuited
3 Motor Clockwise (CW) Check Motor function. Look for Drum “MOTOR
rotation in clockwise direction. CW”
4 Lights/Buttons Lights / Buttons Check all buttons and lights. Press all Button id number
test + Motor test + Motor CW buttons and check for beep and button
CW + igniter ID number in digit display. Check to see
that all Lights function

5 Motor CW + Motor CW + Check Motor and Heater function. Check “HEAT1 - Outlet Control
Heater Heater Outlet Control Thermistor value in digit NTC1” Thermistor value
1 display. (degrees F)
6 Motor CW + Motor CW + Check Motor and Heater function. Check “HEAT2 - Inlet Control
Heater Heater Inlet Control Thermistor value in digit NTC2” Thermistor value
1 + Heater 2 display. (degrees F)
7 Motor CW Motor CW + Check Motor and Heater function. Check “HEAT3 - Outlet Control
+ Heater1 + Heater Outlet Control Thermistor value in digit NTC1” Thermistor
Heater 2 + display. value (degrees F)
Heater 3
8 Motor CW Check for Mist “MIST
VALVE”
9 Error code history display Check last 5 error codes displayed error code
(See Error Code Table )
10 Software version Software version Software Software
version version
11 Lights / Buttons test

3-19
Electronic Control
Error Fault Possible Fault Possible Solutions
Code Conditions
Contact Sensor Electronic Control Board Check Contact Sensor and wiring. If no problems are found with
E31
frequency too high. defective or foreign object Contact Sensor, replace Electronic Control Board.
interfering with contact sensor.
Contact Sensor Electronic Control Board Check Contact Sensor and wiring. If no problems are found with
E32
frequency too low. defective or foreign object Contact Sensor, replace Electronic Control Board.
interfering with contact sensor.
Door Sensing Electronic Control Board Replace Electronic Control Board.
E42
failure. defective.
Motor Relay failure Motor Relay stuck open or If motor runs continuously with power applied check for short circuit
E51
closed; Wiring defective. across motor relay (RL2), or L1 applied to motor relay output (J3-1)
with cycle stopped. If motor does not start when “start” key is pressed,
check for open circuit between L1 and motor relay connection (J3-2).
If no wiring problems found, replace Electronic Control Board.

Motor Fault – Motor overheating; Laundry Remove any load from dryer and check if drum turns freely by hand.
E52
motor stopped or load too heavy; Low power Check L1 power supply voltage, motor wiring, and motor thermal
not starting. supply; Motor, or Wiring defec- protector (if motor thermal protector has tripped, it may take up to 30
tive. minutes to reset).
Motor Centripetal Motor Centripetal Switch, Check wiring. Check if Motor Centripetal Switches are stuck in open
E53
Switch Failure Electronic Control Board or closed positions. Replace motor. Replace Electronic Control Board.
Defective, or wiring defective.
Motor Sensing Electronic Control Board Replace Electronic Control Board and retest.
E54
failure defective
Heater Relay failure. Heater relay stuck open or Check for short circuit across heater relay(s) (RL5, RL6, RL7) or L1
E61
closed; Wiring defective. applied to heater relay output(s) (J5-2, J7-1, J7-3) with cycle stopped.
Check for open circuit between L1 and heater relay connection(s)
(J5-1, J5-3, J7-2). If no wiring problems are found, replace Electronic
Control Board and retest.
Heater to Earth Heating element or wiring Check heater coils and connections for short circuits to the cabinet.
E63
Ground defective Replace heater and/or wiring and retest.
Heater Open Heating element or wiring Check heater coils and connections for open circuits. Replace heater
E64
Circuit defective. and/or wiring and retest.
High Limit High vent restriction, High For Electric Model, check Inlet Thermal Limiter for continuity. If
E65
Thermostat trip Limit Thermostat defective or Thermal Limiter is open, check for evidence of high temperature event
count too high Inlet Thermal Limiter tripped and any resulting damage. If no further damage is evident, replace
(Electric Model only) Thermal Limiter. If no problems are found with Thermal Limiter,
check exhaust vent system for air blockages. If no problems with vent
restrictions, check/replace High Limit Thermostat, and retest.

Thermal Limiter Outlet Thermal Limiter tripped Check Outlet Thermal Limiter for continuity. For Gas Model, also
E66
Open Circuit Inlet Thermal Limiter tripped check Inlet Thermal Limiter for continuity. If Thermal Limiter is open,
(Gas Model only) or wiring check for evidence of high temperature event and any resulting dam-
defective. age. If no further damage is evident, replace Thermal Limiter and
retest.
Heaters Sensing Electronic Control Board Replace Electronic Control Board and retest.
E67 Failure defective.
Outlet Control Outlet Control Thermistor or Check resistance of Outlet Control Thermistor, and check wiring for
E71
Thermistor open wiring defective open circuit. Resistance should be between 4.9K Ohm and 6.2K Ohm
circuit at room temperature (68-77° F or 20-25° C). Replace Outlet Control
Thermistor and/or wiring and
retest.

3-20
Electronic Control
Error Fault Possible Fault Conditions Possible Solutions
Code
E72 Outlet Control Outlet Control Thermistor or wir- Check resistance of Outlet Control Thermistor, and check wiring for
Thermistor short ing defective. short circuit across Thermistor connections. Resistance should be
circuit between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or
20-25° C). Replace Outlet Control Thermistor and/or wiring and retest.

E73 Inlet Control Inlet Control Thermistor or wiring Check resistance of Inlet Control Thermistor, and check wiring for
Thermistor open defective. open circuit. Resistance should be between 47K Ohm and 66K Ohm
circuit. at room temperature (68-77° F or 20-25° C). Replace Inlet Control
Thermistor and/or wiring and retest.
E74 Motor Relay failure Motor Relay stuck open or If motor runs continuously with power applied check for short circuit
closed; Wiring defective. across motor relay (RL2), or L1 applied to motor relay output (J3-1)
with cycle stopped. If motor does not start when “start” key is pressed,
check for open circuit between L1 and motor relay connection (J3-2). If
no wiring problems found, replace Electronic Control Board.

E91 Communication Wiring, Electronic Control Board, Check connections between Electronic Control Board and Interface
Error or Interface Board defective Board. If no wiring problems, replace Electronic Control Board or
Interface Board.

E92 Incompatible Electronic Control Board incom- Check if correct Interface Board console and Electronic Control Board
protocol patible with Interface Board are installed. Replace appropriate hardware.

E93 Machine configu- Wrong configuration data loaded, Check if correct Interface Board and console are installed. Replace
ration checksum Interface Board or Electronic Interface Board and/or console.
error Control Board or wiring defective.
E94 Cycle configuration Wrong configuration data loaded Replace Electronic Control Board.
checksum error. or Electronic Control Board defec-
tive
E97 Program mismatch Wrong configuration data loaded, Replace Electronic Control Board.
Electronic Control Board
defective
EA1 Main Supply Line frequency out of limits or Check frequency of line voltage.
Frequency out of Electronic Control Board faulty.
Range
EA2 Voltage too high Line voltage too high or Electronic Check amplitude of line voltage.
Control Board faulty.
EA3 Voltage too low Line voltage too low or Electronic Check amplitude of line voltage.
Control Board faulty.
EA4 Improper home Line connections in home faulty, Check wiring at terminal block for L1-N-L2 wired incorrectly.
wiring wiring or Electronic Control Board
defective.
EA5 Main V Sensing Electronic Control Board Replace Electronic Control Board.
failure defective
EF1 Vent Blocked High vent restriction, Exhaust Check vent restrictions and resistance values of Exhaust Control
Control Thermistor, Inlet Control Thermistor and Inlet Control Thermistor.
Thermistor, or Electronic Control
Board defective.
EF3 Max Timeout Timer Exhaust blocked; Exhaust Control Check vent restriction, Contact Sensor, and resistance values of
Thermistor, Inlet Control Exhaust Control Thermistor and Inlet Control Thermistor.
Thermistor, Contact Sensor or
Electronic Control Board
defective.
EF8 Key Stuck Console button or Interface Board Check buttons for activation when pressed. Replace console or
defective Interface Board as appropriate

3-21
OPTIONS DRYNESS LEVEL T E M PE R A T UR E

EDM OPTIONS - PROGRAMS


MATRIX

Low

High
Air Fluff

Medium

Sanitize
Damp Dry

Less Dry

(aka Max)
More Dry
Normal Dry

Damp Alert
Delicate Heat
Intended Load

TIMED/AUTO DRY
Wrinle Release
Medium / High

Extended Tumble
Bulky A X X X X X X X X King size comforter
Electronic Control

Heavy Duty A X X X X X X X X X X 16# Jeans


Mixed Load A X X X X X X X X X X 8# Cotton Mix + 6# Perm Press
Towels A X X X X X 12# T owels
Normal A X X X X X X X X X X X X 12# Cotton Mix CU
Casual A X X X X X X X X X 8# Perm Press CU
Fast Dry T X X T BD by testing

PROGRAMS
Delicate A X X X X X X X X 3# Delicate CU
Touch Up T X

3-22
Time Dry T X X X X X X X Any
Damp Alert X X X X X X X X X X X
Extended Tumble X X X X X X X X X X X
Wrinkle Release X X X X X X X X X X

WITH
Delicate Heat X X X X X X X X

OPTIONS
Sanitize X X
Set-up X X X X X X X X X X X X X X

BLE
COMPATIBILITY WHEN
Execution (paused) X X X X X X X X X X X X

AVAILA-
Factory Defaults Are Highlighted BLUE
IQ Touch Available Cycle Settings, Pre-Sets and Options
OPTIONS DRYNESS LEVEL T E M PE R A T UR E

EDM OPTIONS
- PROGRAMS

Low

High
MATRIX

Air Fluff

Sanitize
Medium

Less Dry

More Dry
Maximum
Damp Dry

Damp Alert
Normal Dry

Shrink Guard
Delicate Heat
Maximum Dry
Medium / Low

Medium / High

Wrinle Release
Perfect Tumble

TIMED/AUTO DRY
Extended Tumble
Intended Load

Bulky A X X X X X X X X X X X King size comforter


Heavy Duty A X X X X X X X X X X X X X X 16# Jeans
Mixed Load A X X X X X X X X X X X X X 8# Cotton Mix + 6# Perm Press
Towels A X X X X X X X X 12# Towels
Normal A X X X X X X X X X X X X X X 12# Cotton Mix CU
Casual A X X X X X X X X X X X X 8# Perm Press CU
Active Wear A X X X X X X X X X X X X 3# spandex + 3# lgt. cotton

PROGRAMS
Fast Dry T X X X TBD by testing
Delicate A X X X X X X X X X X X 3# Delicate CU
Touch Up T X X

3-23
Time Dry T X X X X X X X X X X Any
Damp Alert X X X X X X X X X X X X X X X X
Extended Tumble X X X X X X X X X X X X X X X X X
Wrinkle Release X X X X X X X X X X X X X X X
Delicate Heat X X X X X X X X X X X X X

WITH
Shrink Guard X X X X X X X X X X X X

OPTIONS
Sanitize X X X X X

COMPATIBILITY
Perfect Tumble X X X X X X X X X X X X
Set-up X X X X X X X X X X X X X X X X X X X

BLE
WHEN
Execution (paused) X X X X X X X X X X X X X X X

AVAILA-
Factory Defaults Are Highlighted BLUE
Wave Touch Available Cycle Settings, Pre-Sets and Options
Electronic Control
Options
OPT I ONS DR Y NE SS L E V E L T E M PE R A T UR E

EDM OPTIONS
- PROGRAMS

Low

High

TIMED/
Medium
Air Fluff

Sanitize

AUTO DRY
Less Dry

More Dry
MATRIX

Maximum
Damp Dry

Damp Alert
Normal Dry
Electronic Control

Add Steam
Maximum Dry

Shrink Guard
Intended Load

Perfect Tumble

Delicate Heat
Medium / Low

Medium / High

Wrinle Release

Extended Tumble
Bulky A X X X X X X X X X X X King size comforter
Heavy Duty A X X X X X X X X X X X X X X 16# Jeans
Mixed Load A X X X X X X X X X X X X X X 8# Cotton Mix + 6# Perm Press
Towels A X X X X X X X X 12# Towels
Normal A X X X X X X X X X X X X X X X 12# Cotton Mix CU
Casual A X X X X X X X X X X X X X 8# Perm Press CU
Active Wear A X X X X X X X X X X X X 3# spandex + 3# lgt. cotton

PROGRAMS
Fast Dry T X X X TBD by testing

3-24
Delicate A X X X X X X X X X X X X 3# Delicate CU
Perfect Steam T U X X
Time Dry T X X X X X X X X X X A ny
Damp Alert X X X X X X X X X X X X X X X X X
Extended Tumble X X X X X X X X X X X X X X X X X X
Wrinkle Release X X X X X X X X X X X X X X X X
Delicate Heat X X X X X X X X X X X X X X
Shrink Guard X X X X X X X X X X X X X

WITH
OPTIONS
Sanitize X X X X X

COMPATIBILITY
Add Steam X X X X X X X X X X X X X
Perfect Tumble X X X X X X X X X X X X
Set-up X X X X X X X X X X X X X X X X X X X X

BLE
Execution (paused) X X X X X X X X X X X X X X X

WHEN
AVAILA-
Factory Defaults Are Highlighted BLUE
Unchangeable Options = U
Wave Touch with Steam, Available Cycle Settings, Pre-Sets and
Component Teardown

Component Teardown
This section explains how to access and remove components from an Electrolux IQ-Touch™ and Wave-Touch™
Dryer, and has been arranged in such a way as to simulate which components would need to be removed first in
order to gain access to other components. When following a component removal procedure, it may be necessary to
reference another component removal procedure listed earlier in this section.
IMPORTANT NOTE: Before continuing, please take note of the WARNINGS and CAUTIONS below.

BEFORE SERVICING OR MOVING AN APPLIANCE:


• REMOVE THE POWER CORD FROM THE ELECTRICAL OUTLET, TRIP THE CIRCUIT
BREAKER TO THE OFF POSITION, OR REMOVE THE FUSE.
• TURN OFF THE GAS SUPPLY FOR GAS DRYERS.
- IF IT IS NECESSARY TO REMOVE AN ELECTROLUX DRYER UNIT FROM ITS INSTALLATION, USE
PROPER LIFTING TECHNIQUES AS UNITS ARE HEAVY AND COULD FALL RESULTING IN
SERIOUS INJURY OR DEATH. PULLING A UNIT FROM ITS INSTALLATION SHOULD ONLY BE
PERFORMED BY A TRAINED AUTHORIZED SERVICE TECHNICIAN OR INSTALLER.
- TO AVOID ELECTRIC SHOCK, POWER TO A DRYER UNIT MUST BE DISCONNECTED
WHENEVER ACCESSING AND/OR REMOVING COMPONENTS POWERED BY ELECTRICITY OR
COMPONENTS NEAR OTHER ELECTRICAL COMPONENTS.
- IF UNIT WAS USED PRIOR TO SERVICE, THE HEATER ASSEMBLY WILL BE HOT.
WEAR PROTECTIVE GLOVES AND THE APPROPRIATE SAFETY GEAR WHEN WORKING WITH
HEATING ASSEMBLIES.
- AFTER SERVICE IS COMPLETED, BE SURE ALL SAFETY-GROUNDING CIRCUITS ARE COMPLETE,
ALL ELECTRICAL CONNECTIONS ARE SECURE, AND ALL ACCESS PANELS ARE IN PLACE.

- Metal edges may be sharp. Use caution and wear appropriate safety equipment when
servicing dryers to avoid personal injury.
- If working in the motor area, remember that the heater element and tubing may be hot if used prior to
service.

4-1
Component Teardown
This section will describe how to access and remove
serviceable components from the dryer. Unless stated,
the procedure will be the same on all models. Unless
stated, reverse the procedure to reinstall the component. Trim Plug

Door Components
Door Trim Ring Removal
The door is secured to a hinge assembly mounted to the
unit frame. The trim ring must be removed to access
and remove the hinge assembly.
Figure 4-1.
To remove the door assembly:
1. Open the door to a 90 degree angle.
2. Using a #2 square bit screwdriver, extract and save
the trim plug and long, course thread, panhead
screw. (See Figure 4-1)
3. Close the door.
4. Rotate the door trim approximately ¾” counter-
clockwise and pull it away from the front of the door.
(See Figure 4-2)
Trim Ring
Door Assembly Removal
The door assembly is secured with 4 screws to the hinge Figure 4-2.
assembly. It is not necessary to remove the trim ring to
access the hinge screws of the door assembly.
To remove the door assembly:
1. Open the door to a 90 degree angle.
2. Using a #2 square bit screwdriver, extract the four
long, course thread, countersunk hinge screws from
Door Hinge Screws
door. (See Figure 4-3)
3. While supporting the weight of the door with both
hands, separate the door from the hinge.
(See Figure 4-4)
4. Gently place the door face down on a flat, covered
work surface.
Figure 4-3.

4-2
Component Teardown
Latch Plate and Door Latch Removal
The latch plate is secured with two long coarse thread
screws to the inner face of the door assembly. The door
latch is secured to the inside of the latch plate with a
screw and positioned on locating pins. The door latch
may be removed without removing the door assembly.
To remove the latch plate:
1. Using a #2 square bit screwdriver, remove the two
long, course thread, countersunk screws.
(See Figure 4-4) Latch Plate
2. Lift latch plate from door assembly. Screws

3. Using a #2 Phillips head screwdriver from the Figure 4-4.


underside of the latch plate, extract the screw while
compressing the spring assembly. (See Figure 4-5) Locating Screw
4. Slowly release the spring assembly. Pivot the door Pins
latch on the retaining pins so latch is 90 degrees to
the latch plate. Slide door latch off locating pins.

Inner Door Glass Removal


The inner door glass is secured with screws that pass
through two retaining covers that are mounted to the Figure 4-5.
inner door assembly.
To remove the inner door glass:
1. Remove door assembly from unit.
2. Remove the latch plate.
3. Using a #2 square bit screwdriver, extract the screws
from the two retaining covers and pull from door
assembly. (See Figure 4-6)
Screws
4. Lift the inner door glass from door assembly and
remove the rubber gasket from door glass.

Figure 4-6.

4-3
Component Teardown
Latch Indicator Removal
The latch indicator is secured by retaining latches to the
interior of the door assembly.
To remove the latch indicator:
1. Remove door assembly from unit.
2. Remove the latch plate.
3. Grasp the indicator on the latch side between finger Figure 4-7.
and thumb and rock it upward, pivoting away from
the center of the glass. (See Figure 4-7)
4. Gently push the indicator toward the center of the
lens to release the tab.
5. Rock the tab upward. (See Figure 4-8)
6. Pull the indicator out and remove from unit.
(See Figure 4-8)

Door Strike Removal


The door strike is secured with two screws to the front
panel.
To remove the door strike:
1. Open the door to a 90 degree angle.
2. Using a #2 square bit screwdriver, extract the two Figure 4-8.
screws securing the door strike to the front panel.
(See Figure 4-9)

Outer Door Glass Removal


The outer door glass is secured with retaining latches to
the door assembly.
Door Strike
To remove the outer door glass: Screws
1. Remove door assembly from unit.
2. Remove the latch plate.
3. Remove retaining covers.
4. Release the retaining latches around the door
assembly that secure the outer door glass to the
Figure 4-9.
door assembly. (See Figure 4-10)

Retaining Latches

Figure 4-10.

4-4
Component Teardown
Door Hinge Removal
The door hinge is secured with screws to the unit frame.
To remove the door hinge:
1. Remove door assembly from unit.
2. Using a #2 square bit screwdriver, with the hinge
in open position, extract two short, course thread,
panhead screws from hinge plate. (See Figure 4-11)
3. Using a #2 square bit screwdriver, extract 3 short,
fine thread, countersunk screws in hinge side.
(See Figure 4-12)

Figure 4-11.

Lint Trap Removal


The lint trap is removed by simply lifting the lint trap out
from the air duct. The lint trap should be cleaned prior to
each load being dried. (See Figure 4-13)

Air Duct Cover


The air duct cover is secured to the dryer frame with two
screws under the trim ring and two screws in the interior
of the drying compartment.
To remove the front air duct cover:
Figure 4-12.
1. Remove the trim ring and pull lint trap from unit.
2. Using a #2 square bit screwdriver, extract the two
screws that secure the air duct cover to the front
panel. (See Figure 4-14)
3. Using a #2 square bit screwdriver, extract the screw
from each side of the air duct cover securing the air
duct cover to the inside of the drying compartment.
Pull air duct cover straight up until clear of the drying
compartment. (See Figure 4-14)

Figure 4-13.

Screws

Figure 4-14.

4-5
Component Teardown
Top Panel Removal
The top panel is secured with a metal tab at each front
corner and two screws at the rear of the unit.
To remove the top panel:
1. Pull unit from its installation position to access the
Screws
rear of the unit.
2. Using a #2 square bit screwdriver, extract the two Figure 4-15.
screws securing the top panel to the unit frame.
(See Figure 4-15)
3. From the front of the unit, push the top panel
towards the rear until free of the metal tabs, then lift
top panel off of unit.

Screw Electrical Connection Screw


Console and User Interface Removal
The console is secured with a screw on each
corner that passes through a bracket mounted to the
console and fastens into the unit frame. The wire harness
connects to the right hand side of the user interface
mounted inside the console. Retaining
To remove the console: Tab

1. Remove the top panel.


2. Using a #2 square bit screwdriver, extract the screw Figure 4-16.
from each side securing the console mounting
bracket to the top of the unit frame.
(See Figure 4-16) Screws

3. Carefully lift console off the front panel, using care


not to strain wire harness connections.
4. Carefully position the console to access the
electrical connection and disconnect the wire leads
from the user interface.
5. Using a #2 square bit screwdriver, extract the six
screws securing the control assembly to the console
panel. Carefully lift the control assembly from the Figure 4-17.
console panel. (See Figure 4-17)
6. Separate the button carrier from control assembly by
NOTE: When removing the control board, release the
releasing the two retaining latches on the end with
circuit board at the base of the cycle control knob first by
the Start /Pause button. Lift slightly and pull tab out
pushing back the retaining latches and lifting the circuit
of the slot closest to the cycle selector knob.
board out from under the latches. Then continue with the
7. Separate the cycle control knob housing from the removal of the main circuit board.
control assembly by releasing the three retaining
8. The control board and display is removed by pushing
latches on the outer edge of the control assembly.
back the retaining latches securing the control board
Carefully lift up housing until control knob is free of
to the control assembly, then lifting it out of the
shaft, then lift housing off of the control assembly.
control assembly.

4-6
Component Teardown
Front Panel Removal
Screws
The front panel is secured with four screws, two screws
along the top edge and two along the bottom edge.
When removing the panel, use caution not to strain the
door switch electrical leads.
To remove the front panel:
1. Remove the trim ring, door assembly and the air
duct cover.
2. Remove the top panel and console.
3. Using a #2 square bit screwdriver, extract the two
screws from the bottom of the front panel, then the
two screws at the top of the front panel.
(See Figure 4-18)
4. From the inside of the front panel, disconnect the Screws
door switch electrical leads at the Molex connector.

Door Switch Removal Figure 4-18.


The door switch is secured with retaining latches to the
backside of the front panel.
Electrical
To remove the door switch: Connection
1. Remove the trim ring, door assembly and the air
duct cover.
2. Remove the top panel, and console.
3. After extracting the screws securing the front panel
to the unit frame, reach behind the front panel and Retaining
disconnect the wire harness for the door switch at Latches
the Molex connector. The front panel can now be
removed from the unit. (See Figure 4-19)
Figure 4-19.
4. Disconnect the wire leads connected to the terminals
of the door switch.
5. From the backside of the front panel, press in the
retaining latches while pushing door switch through
the front panel. (See Figure 4-19)

4-7
Component Teardown
Control Assembly
Screw Retaining Latches
The control assembly is mounted to a bracket along the
top right hand side of the unit frame. The wire harness
connects to multiple positions on the circuit board and
must be disconnected before removing from the unit.
Electrical
To remove the control assembly: Connection
1. Remove the top panel. Screw
2. Using a #2 square bit screwdriver, extract the two
screws securing the control assembly to the
mounting bracket. (See Figure 4-20)
3. Carefully handle the control assembly while
disconnecting the electrical leads from the control
assembly. Figure 4-20.
4. Release the retaining latches securing the control NOTE: The gas dryer uses the same housing for
assembly cover to the control housing. Lift cover the control board, but will have one less electrical
from housing. connection.
5. The circuit board is secured on one end of the
housing with retainers. Lift from opposite end and
pull out from under retainers to remove the circuit
board.

Control Box Bracket Removal


Tabs
The control box bracket is secured by two retaining tabs
and two screws at the front and rear inner panels.
To remove the control box bracket:
1. Remove the top panel, rear panel, console and
front panel. Screws
2. If replacing the bracket, remove the control box. If
removing the bracket to access the drum or heating Front
components, it is not necessary to remove the Inner
control box. Panel
3. From both ends of the bracket, use a #2 square bit
screwdriver and extract the four screws securing the
bracket to the inner front and rear panels. Figure 4-21.
(See Figure 4-21)
4. Lift upwards to release the tabs, then pull out of the
unit. If control box is still mounted to bracket, swing
bracket over rear inner panel.

4-8
Component Teardown
Interior Light Removal
Rotate Tab
The interior light is an LED assembly that is secured with
a tab that secures the assembly to the inner front panel.
The wire leads for the interior light are disconnected at
the control assembly.
To remove the interior light:
1. Remove the trim ring, door assembly and the air
duct cover.
2. Remove the top panel, console and front panel. LED Assembly
3. Disconnect the wire leads at the control assembly. Figure 4-22.
4. Rotate interior light assembly until tab can be
pushed through the inner panel, then pull assembly
and wire leads through the compartment opening.
(See Figure 4-22)

Top Rear Brace


The top rear brace is secured with five screws to the top
and rear of the unit frame.
To remove the top rear brace:
1. Pull the unit from its installation position and Screws
remove the top panel.
Figure 4-23.
2. Using a #2 square bit screwdriver, extract
the three screws from the lower edge of the
top rear brace. (See Figure 4-23)
3. From the top edge, extract the screw from
each corner of the top rear brace and remove
from unit.

Rear Panel Removal


The rear panel is secured with 21 screws to the unit
frame. The exhaust duct will need to be removed prior to
removing the rear panel.
To remove the rear panel:
1. Pull the unit from its installation position and remove
the top panel and rear top brace.
2. Using a #2 square bit screwdriver, extract the 21
screws ( Labeled “A” in Figure 4-24) securing the
rear panel to the rear of the unit. Remove the rear
panel from unit.

Figure 4-24.

4-9
Component Teardown
Inlet Thermistor Removal (Inlet NTC)
The function of the rear inlet thermistor / Inlet NTC is to Screw
determine the heater status. If the temperature reads
over the threshold, the heater(s) will be turned off. A
faulty inlet NTC may prevent the heater(s) from turning
on, or may turn the heater(s) off prematurely.
The inlet thermistor is inserted into the outlet of the heat
duct to sense the temperature of the air prior to entering
Heat
the drying compartment. A screw secures the inlet
Duct
thermistor to the outside of the heat duct. Electrical Connection
To remove the inlet thermistor:
Figure 4-25.
1. Remove the top panel, top rear brace and rear
panel.
2. The inlet thermistor is mounted to the top left
hand side of the heat duct. Using a #2 square bit
screwdriver, extract the screw securing the inlet
thermistor to the heat duct. (See Figure 4-25)
3. Pull inlet thermistor from heat duct.
4. Disconnect inlet thermistor from from wire
harness at the Molex connector.

Moisture Sensing Bar Removal Screw

The moisture sensing bar is mounted to the lower back


wall of the drying compartment and secured with a screw.
The electrical connections are accessible only with the
rear panel removed.
To remove the console panel:
1. Remove the top panel, top rear brace and rear
panel. Figure 4-26.
2. Disconnect the electrical leads from the sensor
bar terminals. (See Figure 4-26)
NOTE: The electrical connection can be disconnected at Electrical Connection
the molex connector and with the removal of the ground
wire screw as shown in Figure 4-27. Tab
3. From inside the drying compartment, extract
the screw securing the moisture sensing bars
to the back wall. (See Figure 4-27)
4. Lift the screw end of the moisture sensing bars
up and away from the back wall until tab is
free of the back wall. Ground
Wire

Figure 4-27.

4-10
Component Teardown
Belt Removal (Wave Touch™)
The belt circles the drum and has tension applied to it by
the idler arm assembly.
To remove the belt:
1. Remove the top panel, rear panel, console and
front panel.
Belt
2. From the rear of the unit, reach under the drum
and pull the idler arm assembly to the left and
release the belt from the roller guides and motor
pulley. (See Figure 4-28)

Idler Arm Assy.


Belt Removal (IQ Touch™) Figure 4-28.
The belt circles the drum and has tension applied to it by
a spring mounted between the idler arm assembly and Belt
the motor mount.
To remove the belt:
1. Remove the top panel, rear panel, console and Spring
front panel.
2. From the rear of the unit, reach under the drum
and pull the idler arm assembly to the right and
release the belt from the roller guides and motor
pulley. (See Figure 4-29)

Idler Arm
Front Inner Panel and Drum Removal
Figure 4-29.
The front inner panel, which is secured to the unit frame
with four screws and two retaining tabs at the top, must
be removed to remove or replace a belt. The front air
duct is removed with the front inner panel as one
assembly.
1. Remove the top panel, rear panel, console,
front panel, and interior light, then release the
belt from motor.
2. Using a #2 square bit screwdriver, extract Screws
the four screws securing the inner front panel
to the unit frame. (See Figure 4-30)
NOTE: It is recommended to have a second person to
help remove the drum as the front inner panel is removed
from the unit.
3. Lift the front inner panel up to release the retaining
tabs, then outward. The drums front edge will fall
from the ledge of the inner front panel and guide
rollers unless otherwise supported.
4. Remove drum from unit by pulling the side panels
outward, then pulling the drum from the unit.

Figure 4-30.

4-11
Component Teardown
Roller Assembly Removal Retainers
Inner
There are five roller assemblies that the dryer drum rides Panel
upon. The roller shafts are secured to the outside of the
inner panels by a 9/16” nut. The rollers slide onto the
roller shafts and are secured with triangular retainers.
To remove the roller assemblies:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
NOTE: With the drum removed, all roller assemblies Roller
are accessible. Figure 4-32 illustrates the front roller 9/16”
assemblies. Nut Washers

2. Using a 9/16” socket or wrench, remove the nut from Figure 4-31.
the roller shaft securing it to the inner panel. A 3/8”
wrench can be used on the opposite end of the shaft
to stop the shaft from turning while loosening and
tightening the nut. (See Figure 4-31)
3. Pull roller assembly from inner panel.
4. Use a small flat bladed screwdriver and remove the
triangular retainer from the roller shaft. Pull the roller
from the roller shaft.

Front Air Duct Removal


Screw
The front air duct is secured with three screws to the
inner front panel. The two screws behind the rollers are
only accessible with the inner panel removed from the
unit. Rollers
To remove the front air duct:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
Front Air Duct
2. From the backside of the front inner panel, use
a small flat bladed screwdriver and remove the
triangular retainer from the two roller shafts. Pull the
rollers from the roller shafts.
Figure 4-32.
3. Using a #2 square bit screwdriver, extract the three
screws securing the front air duct to the front inner
panel. (See Figure 4-32)

4-12
Component Teardown
Exhaust Thermal Limiter Removal
(Electric and Gas Models)
Exhaust
The exhaust thermal limiter is mounted with screws to the
Duct
right side of the exhaust tube and is accessible from the
rear of the machine.
To remove the exhaust thermal limiter:
1. Remove the top panel, rear top brace and the rear Screws
panel.
2. From the rear of the unit, disconnect the wire leads
from the exhaust thermal limiter terminals.
3. Using a #2 square bit screwdriver, extract the two
screws securing the exhaust thermal limiter to the
exhaust tube. (See Figure 4-33)
Figure 4-33.

Exhaust Tube Removal (Electric and Gas Models)


Rubber Seal
The exhaust tube is secured at the rear of the unit with Electrical
a screw to the unit base. A rubber seal slides over the Connection
connection between the exhaust tube and the blower
assembly.
To remove the exhaust tube:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum. Screw
2. Disconnect the wire leads from the exhaust thermal
limiter terminals. Slide rubber seal onto the exhaust
tube. (See Figure 4-34)
3. Using a #2 square bit screwdriver, extract the screw
securing the exhaust tube to the unit base. Pull tube
out of blower assembly outlet. Figure 4-34.

Outlet (Exhaust) Thermistor Removal Blower Outlet Duct


(Electric and Gas Models)
The outlet thermistor is mounted with a screw to the front Screw
of the exhaust side of the blower outlet ducting.
To remove the outlet thermistor:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
2. Disconnect the wire leads from the outlet thermistor
terminals.
3. Using a #2 square bit screwdriver, extract the screw Electrical
Connection
securing the outlet thermistor to the blower outlet
duct. (See Figure 4-35)
Figure 4-35.

4-13
Component Teardown
Belt Tensioner Removal
“C” Clip 3/8” Nut
(Wave Touch)
The belt tensioner is secured to the rear of the motor
assembly with a 3/8” bolt. The belt
tensioner may be accessed without removing the motor
from its installation position.
To remove the belt tensioner:
1. Remove the top panel, top rear brace and rear
panel. Release the belt from the belt tensioner. Idler Pulley
2. Using a 3/8” socket or wrench, remove the bolt
securing the belt tensioner to the motor mounting 3/8” Bolt Lock
bracket. (See Figure 4-36) Washer
3. The idler pullies are removed from the belt tensioner Figure 4-36.
arms by using a 7/16” socket or wrench for the nut,
and a flat blade screwdriver in the flat on the
opposite end of the shaft to prevent the shaft from
turning.
NOTE: The idler pullies may be removed by removing the
“C” clip from the front of the idler shaft.

Belt Tensioner Removal Idler Pulley


(IQ Touch)
The belt tensioner is secured to the rear of the motor
assembly with a 3/8” bolt. A spring, mounted to the
Spring
motor mount assembly, provides tension to the idler arm
and belt. The belt tensioner may be accessed without
removing the motor from its installation position.
To remove the belt tensioner:
1. Remove the top panel, top rear brace and rear
panel. Release the belt from the belt tensioner.
2. Using a 3/8” socket or wrench, remove the bolt Idler Arm
securing the belt tensioner to the motor mounting
3/8” Bolt
bracket. (See Figure 4-37)
3. The idler pullies are removed from the belt tensioner Figure 4-37.
arms by using a 7/16” socket or wrench for the
nut, and a flat blade screwdriver in the flat on the
opposite end of the shaft to prevent the shaft from
turning.
NOTE: The idler pullies may be removed by removing the
“C” clip from the front of the idler shaft.

4-14
Component Teardown
Motor and Blower Assembly Removal
Motor Wire Harness
(Electric and Gas Models)
The motor bracket is secured by a large retaining tab that
slides under the unit base and two screws that fasten into Motor
the unit base. The motor is secured to the bracket with a Mounting
spring clip at the pulley end and with a retaining bracket Bracket
to the blower assembly. The blower wheel is mounted to Tab
the motor shaft with a left hand thread and secured with
a nut.
To remove the motor:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
2. Disconnect the wire harness connection from the Screws
motor. Figure 4-38.
3. Using a #2 square bit screwdriver, extract the screws
securing the motor assembly to the unit base.
(See Figure 4-38)
4. Extract the screw securing the blower outlet
thermistor to the blower assembly and then pull from
blower assembly. (See Figure 4-39)
5. Extract the two screws securing the blower assembly
to the unit base. (See Figure 4-39)
6. Push the rubber seal covering the exhaust tube and
blower assembly connection onto the exhaust tube.
Pull the motor and blower assembly towards the
front of the unit until the tab on the motor mounting
bracket releases from the unit base, then pull until
assembly is free of the exhaust tube.
Screws

Figure 4-39.

4-15
Component Teardown
Motor and Blower Assembly Separation
(Electric and Gas Models)
7/8” Nut
To separate the motor from the blower assembly, remove
the motor and blower assemblies by
following steps 1-6 on the previous page and shown in
figures 4-38 & 4-39, then follow the steps below. 7/16” Nut

1. Using a 7/16” extended socket, remove the nut


securing the motor shaft to the blower wheel.
(See Figure 4-40) Figure 4-40.
2. Using a 7/8” extended socket and while holding the
Tab
motor shaft from turning, loosen the blower wheel
from the shaft by turning clockwise. Spin blower
wheel clockwise until free of motor shaft.
(See Figure 4-40)
3. Using a small flat bladed screwdriver, lift the blower
housing lock over the tab and pull out of slot.
(See Figure 4-41)
4. Using a pliers, grab the motor clip at its outer edge, Motor
then push down and away from the motor mounting
bracket until free of retaining tab. Remove motor clip
from motor assembly. (See Figure 4-42 Figure 4-41.
5. Lift the motor off the motor mounting bracket and pull
motor out from the blower assembly.

Grab Here
With Pliers

Figure 4-42.

4-16
Component Teardown
Drum Vane Removal (Electric and Gas Models)
The drum vanes are secured with screws that pass Screws
through the drum and fasten into the vanes.
To remove the drum vanes:
1. Remove the top panel.
2. Rotate the drum to access the screws on the exterior
of the drum. While supporting the drum vane, use
a #2 square bit screwdriver and extract the screws
securing the drum vanes to the interior of the drum.
(See Figure 4-43)
Figure 4-43.

Screw
Rear Heat Duct Removal
The rear heat duct is secured with three screws to the
rear inner panel. A thermistor is mounted to the rear
upper right hand side of the heat duct and is secured with
Inlet
a screw. Thermistor Rear Air
To remove the rear heat duct: Duct

1. Remove the top panel, rear panel, console, front


panel, front inner panel and drum. Figure 4-44.
2. From the rear of the unit, remove the inlet thermistor.
(See Figure 4-44)
3. From the inside of the inner panel, using a #2 square
bit screwdriver and extract the screws securing the
rear air duct to the rear inner panel. Pull the rear air
duct from the rear inner panel. (See Figure 4-45)

Heat Shield Removal (Electric Models)


NOTE: If unit was used prior to service, the heater Screws
assembly may be hot. Refer to Warnings and Cautions at
the beginning of this section.
The heat shield is secured with a screw to the mounting
bracket for the heater assembly.
Figure 4-45.
To remove the heat shield:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
2. Using a #2 square bit screwdriver, extract the screw
securing the heat shield to the heater mounting
bracket. (See Figure 4-46) Screw

Figure 4-46.

4-17
Component Teardown
Electric Heater Function
The electric heater assembly consists of three 5500
Watt elements, that are energized as needed by the
electronic control. Under normal circumstances where
the unit is starting at ambient temperature (below 100°F),
all heating elements should turn on. Above 100°F (in
the exhaust), any number of heating elements may be
on depending on selected cycle, temperature settings,
options and previous state of elements. Unless there
is a high vent restriction or faulty thermistor, the heater
element conditions will be controlled by the exhaust NTC.

Heater Assembly Removal (Electric Models)


NOTE: If unit was used prior to service, the heater
assembly may be hot. Refer to Warnings and Cautions at
the beginning of this section.
The heater assembly is secured to a mounting bracket
in the front and secured with two screws. The rear of
the heater slides into the heat duct and is secured with a Screw
screw to the right rear of the heater assembly.
1. Remove the top panel, rear panel, console, front
panel, front inner panel, drum and heat shield. Electrical
2. Disconnect all wire leads from the components Connections
mounted to the heater assembly, labeling as needed
to assure proper connection.
3. Using a #2 square bit screwdriver, extract the two
screws at the front of the heater assembly and the
single screw at the right rear. (See Figure 4-47)
4. Pull the heater assembly from heat duct.

Screws
Thermal Limiter and Safety Thermostat Removal
(Electric Models)
Figure 4-47.
The thermal limiter and safety thermostat are mounted
to the left side of the heater assembly and secured in
position with screws.
To remove the thermal limiter and safety thermostat:
1. Remove the top panel, rear panel, console, front Safety
panel, front inner panel and drum. Thermostat
2. Disconnect the electrical leads from the thermistor
that is to be checked or replaced. Thermal
3. Using a #2 square bit screwdriver, extract the two Limiter
screws securing the thermistor mounting bracket to
the heater assembly. (See Figure 4-48)

Figure 4-48.

4-18
Component Teardown
Gas Heater Assembly Breakdown
The gas heater assembly consists of the supply manifold
pipe, gas valves and coils, ignitor, burner and combustion ALWAYS SHUT OFF THE GAS SUPPLY BEFORE
tube with sensors. SERVICING A GAS DRYER.

Thermal Limiters Removal (Gas Models) Safety


Thermostat
The thermal limiter and safety thermistor are mounted to
the upper left hand side of the combustion tube assembly. Heater
Assembly
To remove the thermal limiter and safety thermistor: Tube
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum. Thermal
Limiter
2. Disconnect the electrical leads from the thermal
limiter and safety thermistor.
3. Using a #2 square bit screwdriver, extract the screws
securing the sensors to the combustion tube.
(See Figure 4-49) Figure 4-49.

To Gas Valve Coils


Gas Valve Wire Harness Connections (Gas Models)
To remove the wire harness connections:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum. To Ignitor
2. Label the connections as needed prior to
disconnecting.
3. Disconnect from the Molex connectors for the
ignitor, sensor and main wire harness.
(See Figure 4-50) To Sensor
4. Disconnect wire leads from gas valve coil terminals.

Gas Valve Coil Removal (Gas Models)


The gas valve coils are secured by a bracket that has two To Control
screws fastened into the gas valve body. Small plastic
pins locate the coils for proper alignment. Figure 4-50.

To remove the gas valve coils:


Screws
1. Remove the top panel, rear panel, console,
front panel, front inner panel and drum.
2. Disconnect the two wire harness leads from
the gas valve coil terminals. DO NOT
3. Using a #2 Phillips head screwdriver, extract GRIP
two screws securing the coil bracket to the HERE
valve body. Remove bracket from valve body.
(See Figure 4-51)
Plastic Coil
4. Pull coils from valve body.
Pins

Figure 4-51.

4-19
Component Teardown
Manifold and Burner Assembly Breakdown
(Gas Models) Valve Mounting
Bracket Screws
In order to separate the manifold from the valve body, the
burner assembly must be removed from the valve body. Screw
A screw at the rear of the unit secures the manifold to the
rear frame as well as two screws securing the manifold
to the unit base. All electrical connections should be
disconnected prior to removing the manifold.
To remove the manifold and burner assembly:
1. Remove the top panel, console and front panel.
2. Disconnect all electrical connections from gas valve,
coils, ignitor and wire harness. (See Figure 4-52) Screws
3. Using a #2 square bit screwdriver, extract the screw
from the rear of the unit base securing the manifold
mount to the unit base. (See Figure 4-52)
Figure 4-52.
4. Extract the two screws from the manifold mount
located beneath the combustion tube.
(See Figure 4-52) Screws
5. Extract the screw from the bent down tab at the
entrance of the combustion tube. (See Figure 4-52)
6. The gas valve and burner assembly with the
manifold attached, can now be pulled out of the
combustion tube.
7. Using a #2 square bit screwdriver, extract the screws
securing the burner assembly to the gas valve Ignitor Screw
mounting bracket. (See Figure 4-53)
8. Extract the four screws securing the gas valve Figure 4-53.
mounting bracket to the gas valve and manifold.
Remove the gas valve mounting bracket from the
assembly. (See Figure 4-52)
9. Extract the screw securing the ignitor to the gas
valve mounting bracket. Lift the ignitor off the tab
and remove from bracket. (See Figure 4-53)
10. Separate the manifold from the gas valve by using
a 1-3/16” open end wrench or a large adjustable
wrench, and grabbing the gas valve body on the
square section directly above the manifold. Turn gas
valve body counter clockwise to remove.
Manifold
(See Figure 4-54)

Figure 4-54.

4-20
Component Teardown
Combustion Tube Removal (Gas Models)
Safety
The combustion tube is secured to a mounting bracket Thermostat
in the front and secured with two screws. The rear of the
combustion tube slides into the heat duct and is secured
with a screw to the right rear of the combustion tube.
To remove the combustion tube:
1. Remove the top panel, rear panel, console, front
panel, front inner panel and drum.
2. Remove burner and gas valve assembly. Screws
3. Disconnect the safety and thermal limiters from wire
Thermal Limiter
harness.
4. Using a #2 square bit screwdriver, extract the two
screws at the front of the combustion tube and the
single screw at the right rear. (See Figure 4-55)
5. Pull the combustion tube from heat duct.

Figure 4-55.

4-21
Component Teardown

Notes

4-22
Troubleshooting
The following troubleshooting chart involves problems arising from improper drying techniques and are not valid
service issues. Many drying problems involve poor cleaning results, poor soil and stain removal, residues of lint and
scum, and fabric damage. For satisfactory drying results, follow these suggestions provided by The Soap and
Detergent Association.
For Troubleshooting the electronic control and error codes, See Section Three Electronic Control.

Problem Cause Correction


Greasy, oily 1. Fabric softener sheet. 1. Rub fabric softener stains with bar soap.
stains Rinse and rewash.
2. Place fabric softener sheet on top of load
before starting the dryer.
3. Some “silk-like” fabrics should be air dried.
4. Add a few bath towels to small loads for
proper tumbling.
5. Use proper drying temperature.

Lint 1. Overloading. 1. Reduce load size and rewash using liquid


2. Overdrying causes static fabric softener in the final rinse.
electricity. 2. Or, add a fabric softener sheet and tumble
3. Lint screen not clean when without heat.
cycle began. 3. Use lint brush or roller to remove lint.
4. Lint is attached to “pills.” 4. Check that lint filter is clean and in place.

Pilling 1. Overdrying. 1. Use a lint brush or shaver to remove pills.


(Fibers break 2. Use fabric softener to lubricate fibers.
off, ball up and 3. Turn items inside out to reduce abrasion.
cling to fabric.) 4. When ironing, use spray starch or fabric
finish on collars and cuffs.

Shrinking 1. Temperature too high. 1. Irreversible condition.


2. Overdrying. 2. Follow fabric care label directions.
3. If shrinking is a concern, check load often.
4. Remove items while slightly damp and hang
or lay flat to complete drying.
5. Block knits into shape.

Wrinkling 1. Overloading. 1. Reduce load size and tumble at medium or


2. Leaving items in dryer after low heat for 5-10 minutes.
cycle ends. 2. Remove items immediately. Hang or fold.

5-1
Troubleshooting
The following troubleshooting chart involves common concerns that are not the result of defective workmanship
or materials in this washer. Some problems below involve improper installation and issues arising from the users
household water supply. See the Use and Care guide for the unit in question and the Installation Section in this
manual.

Problem Cause Correction


Dryer does not start. 1. Electrical power cord is not 1. Make sure the plug fits tightly in wall outlet.
securely plugged in or plug
may be loose.
2. House fuse blown or circuit 2. Reset circuit breaker or replace fuse.
breaker tripped.
3. Thermal limiter tripped. 3. Test and replace thermal limiter.

LCD displays 1. Dryer has been programmed 1. Turn the cycle selector knob to SPIN
“DEMO MODE”. to temporarily perform a ONLY/TIME DRY cycle, press the START
repeating demo cycle. button then the CANCEL button.
2. Activate the controls by turning the cycle
selector knob and turn to TIME DRY cycle.
3a.Press and hold CANCEL button and CTRL
LOCK button for 3 seconds. (IQ Touch)
3b.Press and hold CANCEL button and
EXTENDED TUMBLE (Third button from the
left) for 3 seconds. (Wave Touch)
Dryer runs but won’t 1. There are 2 house fuses in 1. Replace fuse.
heat. the dryer circuit. If 1 of the 2
fuses is blown, the drum may
turn but the heater will not
operate. (electric models) 2. Check to make sure supply valve is open.
2. Gas supply valve is not open See INSTALLATION INSTRUCTIONS for
(gas models). procedure.
3. Dryer does not have enough 3. See INSTALLATION INSTRUCTIONS.
air supply to support the
burner flame (gas models).
4. LP gas supply tank is empty 4. Refill or replace tank. Dryer should heat
or there has been a utility when utility service is restored.
interruption of natural gas
(gas models).

Drying cycle takes 1. Lint filter is clogged with lint. 1. Make sure all lint has been removed from dryer lint
too long, outside of filter before starting each cycle.
the dryer feels too 2. Exhaust duct requirements 2a. Exhaust duct must be at least 4 in. dia. and made of
hot or smells hot. have not been met. rigid or semi-rigid metal.
2b. When in place, the duct must have no more than
two 90° bends and must not exceed length listed in
INSTALLATION INSTRUCTIONS.
3. Electric dryer is connected to 3. Drying time will be 20% longer than drying on a 240
a 208 volt circuit. volt circuit.
4. Drying procedures have not 4. See “Operating Instructions.”
been followed.
5. Outside exhaust hood or 5. Clean out any obstruction.
exhaust duct may be clogged
or restricted.
6. High humidity. 6. Use a dehumidifier near the dryer.

5-2
Troubleshooting
Problem Cause Correction
Scratching or 1. Foreign objects such as 1. Always remove foreign objects from
chipping of the drum coins, pins, clips or pockets before laundering. Remove objects
finish. buttons are inside the dryer.* from drum and restart dryer.
2. Permanently attached items 2. It may be necessary to sew a scrap of
such as belt buckles, zippers material securely around ornaments before
and fasteners may be hitting drying to prevent scratching and damage to
the inside of the drum.* the dryer.
NOTE: *Drum damage caused by foreign
objects or permanently attached items is not
covered by the warranty.

Electrical Tests For Electric and Gas Dryers


Continuity
When measured by an Ohm meter, there should be no more than .1 Ohms resistance between the
terminal block ground and any exposed metal dryer cabinet component including control shafts and switches when
probed through or in any unpainted area.
Check continuity between motor frame and motor support bracket using a continuity light. Test light must illuminate
when probing the motor frame with one end of the test light and the motor bracket with the other.
If dryer fails continuity with a low voltage tester, check continuity using 120 VAC.

Insulation Dielectric Strength

Disconnect ground link from the neutral of the terminal block on the dryer. With the dryer completely assembled and
with the door closed, apply 1200 VAC or more for one second to the terminal block
terminals or service cord.
Connect one probe to all three terminals and the other probe to the backsheet. There shall be no more than 5mA of
current during the one second test interval. During the 1 second test, no drop in voltage below 1200 VAC is permis-
sible.

Motor Power

Audit - (power required after 20 seconds with no load, motor CW direction, and no heat) 200 to 280 watts.
Line Test - (power required after 1-5 seconds with no load, motor CW direction, and no heat) 210 to 290 watts.

Low Voltage Start

The dryer motor should start and operate at 100 volts (200 volts for 230 VAC, 50Hz dryers). The power will be set to
not dip below this voltage during any part of the cycle. Increase the voltage to allow for meter error and line fluctua-
tions. Test the run with a 50 pound clothes load (25 pounds at 100% moisture) at “Maximum” heat setting.

Motor Protector Trip Time

When the motor is locked, the thermal protector must open to shut off motor within 3 to 10 seconds. This test also
applies to the 50/60 Hz Motor when test is conducted at 230VAC 60 Hz.
NOTE: Tests must be run with a cold (ambient) motor. When tested in the unit, a jumper harness will be needed
to bypass the software alarm for the motor not starting. Without the jumper, the software will stop the cycle within 3
seconds (before the thermal protector opens) if motor movement is not detected.
Tests must be run at 120VAC (line voltage not to sag below this value when the rotor is locked), unless specified
otherwise.

5-3
Troubleshooting
Electrical Tests For Electric Dryers Only
High Limit Thermostat Cycle Time
Trip:
Run the following test at room temperature. Set Time Dry cycle for 30 minutes and the heat selection at maximum
setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door
switch held closed by tape or similar means. The thermostat must open (heater off) between 35 to 120 seconds.

Reset:
When the exhaust block is removed and the door closed (keep tape over door switch), the thermostat must reset
(heat on) within 120 seconds.

Thermal Limiter Trip Time


Run the following test at room temperature. Set Time Dry cycle for 30 minutes and the heat selection at maximum
setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door
switch held closed. The thermal limiter should trip and shut off the heaters after 1 to 5 minutes of operation. To
enable this test, the High Limit Thermostat must be bypassed and NTC2 should be removed from the heat duct.
NOTE: This test renders the thermal limiter inoperative, a new thermal limiter must be installed after this test.

Drum Temperatures
The following tests should be run with an unrestricted exhaust. The location of the thermal couple is to be the
square in the lint grill which is 12 squares left from the right edge of the lint blade and (2) squares
forward. The tip should extend 1.25” into the air grill. Set the dryer timer as needed for each test. The recordable
temperature is to be the maximum temperature following the heater off of the 3rd cycle.
No load is to be used for the following heat settings:

Heat Setting Thermistor Status Temperature (F)


Max* Satisfied/Heater Off 120 to 160
Medium* Satisfied/Heater Off 110 to 140
Low* Satisfied/Heater Off 95 to 130

* Each opening temperature should be equal to or higher than the opening temperature for the next lower tempera-
ture setting.

5-4
Troubleshooting
Electrical Tests For Gas Dryers
Manifold Pressure
Connect manometer to pressure tap on gas valve. During burner operation, manometer reading should be between
2.9 and 4.0 inches of gage oil.

Flames Entering Drying Chamber


Block exhaust and inspect flame length. The flames should not be entering the drying chamber.

Flash Back Into Burner


With exhaust blocked, inspect for flash back into burner during ignition.

Flame Failure
Shut off manual gas valve to extinguish flame. Sensor must shut off gas valve within 90 seconds.

Power Interruption
Interrupt power momentarily for 2 seconds, motor should not continue to run when power is restored. Valve should
not open when power is restored until ignition device is re-energized.

Carbon Deposit
Inspect heater housing and burner tube for carbon deposits after testing.

Ignition Time
Time required for glow bar to light gas: 50 sec. max.

Ignition Power
Power required for glow bar to light gas: 550 - 850 W

Minimum Operating Voltage


Dryer and gas valve to function properly at 100 Volts.

Reduced Gas Pressure


Reduce gas pressure to 1.0 inch in gage oil. Stop and then restart dryer. Allow gas ignition system to recycle and
check to see that ignition is obtained.

Static Pressure
Static pressure at the exhaust exit (when using a 100% exhaust block), as measured by a manometer, shall be 1.6
inch of gage oil, minimum.

High Limit Thermostat Cycle Time Trip


Trip:
Run the following test at room temperature. Set the control board cycle time for 30 minutes and the heat selection
for regular fabrics (max heat setting).
Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door switch
held closed by tape or similar means. The thermostat must open (heater off) between 25 to 110 seconds.

Reset:
When the exhaust block is removed and the door closed (keep tape over door switch), the thermostat must reset
(heat on) within 120 seconds.

5-5
Troubleshooting
Electrical Tests For Gas Dryers
Thermal Limiter Trip Time
Run the following test at room temperature. Set Time Dry cycle for 30 minutes and the heat selection at maximum
setting. Place a 100% exhaust block on the exhaust pipe. The dryer door should be open for this test and the door
switch held closed. The thermal limiter should trip and shut the dryer off after 1 to 5 minutes of operation. To enable
this test, the High Limit Thermostat must be bypassed and NTC2 should be removed from the heat duct.
Note: This test renders the thermal limiter inoperative, a new thermal limiter must be installed after this test.

Drum Temperatures
The following tests should be run with an unrestricted exhaust. The location of the thermal couple is to be the
square in the lint grill which is 12 squares left from the right edge of the lint blade and (2) squares
forward. The tip should extend 1.25” into the air grill. Set the dryer timer as needed for each test. The recordable
temperature is to be the maximum temperature following the heater off of the 3rd cycle.
No load is to be used for the following heat settings:

Heat Setting Thermistor Status Temperature (F)


Max* Satisfied/Heater Off 120 to 180
Medium* Satisfied/Heater Off 105 to 145
Low* Satisfied/Heater Off 95 to 130

* Each opening temperature should be equal to or higher than the opening temperature for the next lower
temperature setting.

5-6
Wiring Schematics
Model EIED55H

6-1
Wiring Schematics
Model EIGD55H

6-2
Wiring Schematics
Model EWED65H

6-3
Wiring Schematics

Model EWGD65H

6-4
Wiring Schematics
Model EWMED65H

6-5
Wiring Schematics
Model EWMGD65H

6-6

You might also like